Main gas Line connections for Propane gas and
Natural gas
The main Fuel supply gas line is connected to
a Manifold Tee securely mounted inside the
pedestal located on the left hand side of the
pedestal.
Remove the Propane hose and regulator as-
sembly from the packaging. Please ensure
Once the Main Gas line has been connected,
connect the fuel line to the Gas supply being
used. Turn the gas on SLOWLY, if the gas is
turned on too quickly the Regulator could lock
up and not work correctly. By turning the main
gas supply on slowly this will prevent this prob-
lem from happening.
that there is no debris inside the brass flare
connection or inside the rubber hose. Using a
¾" wrench and an adjustable wrench tighten
the Hose to the connection provided inside the
pedestal.
Place the Propane Hose and
regulator on the Manifold
located inside the pedestal.
When the gas supply has been turned on, per-
form a Leak Check on ALL connections inside
the pedestal using a Soapy water solution as
described on Page 7 of this manual.
NL
FR
ES
EN
65