MONITOR PROGRAMMING
Option 1: From Plate + Monitor
To program the monitors from the MDS Digital plate/guard unit, please consult the advanced manual for
the VDS decoder, ref. 2409 (code 97651). Available at www.fermax.com
Option 2: From the Monitor
1. Enter configuration mode: Press the
and a confirmation tone is heard.
2. Set the monitor in programming mode: With the monitor connected, press the programming button
for 1 second.
At this point, the call number currently programmed is indicated by means of high-pitched tones. First,
the Hundreds, then Tens, and finally the Units.
To separate each unit, the LED comes on and a lower tone is heard.
3. Program the call number: Every time the button corresponding to hundreds, tens or units is
pressed, the figure increases by one.
Hundreds: Press the
Tens: Press the
Units: Press the
4. Exit programming: Press the programming button or wait for 30 seconds without pressing any buttons.
When you exit prgramming mode, the number indicated is stored. If it is correct (between 1 and
199), a confirmation tone is heard. If it is not correct, an error tone is heard.
1
(5 sec.)
button for 2 seconds. The LED blinks once per second
button
button
button
2
Current no:12
0
moc
beep
moc
If 9 is reached and the button is pressed
again, an error tone is heard. The next
button pressed starts off from number1.
3
1
2
beep
beep
moc
4
1 7