Signal clamps
When it is not possible to connect to a pipe or cable using a direct connection lead, a
transmitter signal clamp can be connected to the accessory socket of the transmitter
and the output signal can be applied. This is particularly useful with live cables as it
removes the need to disable the power and break into the line.
To locate or indentify individual lines a locator signal clamp can be connected to the
accessory socket of the locator and can be clamped around individual cables or pipes
that are bunched together.
Radiodetection supplies a range of signal clamps to suit many applications.
Stethoscopes
At times, it may not be possible to use a locator to locate or identify a particular target
line due to inaccessibility. In these situations a stethoscope antenna should be used to
locate or identify individual target lines.
Radiodetection supplies a range of stethoscopes to suit most applications. To use a
stethoscope, connect it to the locators accessory socket. The locator will automatically
detect the device and filter out location modes that are irrelevant.
Locating sondes
Sondes are battery powered transmitters that are useful for tracking non-metallic pipes
and can be fitted to flexrods and inserted into pipes and ducting etc. The RD7000+ PL,
DL and TL models can detect a range of sonde frequencies, including those transmitted
by FlexiSondes and the P350 flexitrax
crawler.
For a detailed guide on locating sondes, please refer to the RD7000+ Operation Manual.
Fault-finding
The RD7000+ TL and PL models have the ability to detect sheath cable faults
accurately using an accessory A-Frame. The Tx- and Tx-10 transmitters provide a fault
finding signal that can be detected with an A-frame, which occurs whenever there is
damage to cable sheaths.
For a detailed guide to fault-finding, please refer to the RD7000+ operation manual.
Using accessories
Radiodetection have designed a range of accessories to use with the RD7000+ locators
and transmitters. These accessories can be used on a wide range of applications for
applying signals to target lines, fault finding on cables, identifying individual target lines
and locating plastic pipes etc. Applicable RD4000 accessories are compatible with the
RD7000+ locator and transmitters.
For detailed information on accessories please see the RD7000+ operation manual
or go to www.radiodetection.com.
1

Centros Manager

Centros Manager is a Radiodetection PC application which is available as a free
download. From time to time Radiodetection will release new software for the RD7000+
locator and transmitter which may improve performance, stability and may include new
features. The latest software is contained within Centros Manager and to download the
latest software you must register for extended warranty (see page  for details). Once
registered you will receive an email when new versions of software are available and you
may also carry out an eCAL to validate the calibration and functionally test the RD7000+
locator.
Installing Centros Manager
Note: Before download you are advised to view or download the Centros Manager
operation Manual by going to www.radiodetection.com/centrosmanager.
Note: When you install Centros Manager onto a PC, the following message may
be displayed: "You need to log in as Administrator". If this message is displayed,
the installation of the program will not complete. You will need to log on as an
Administrator or ask a user with Administration Rights to install the program on your
behalf. Having successfully installed Centros Manager, the Administrator will need to
carry out the instructions in Section 7.1 of the Centros Manager Operation Manual if
they wish users without Administrator Rights to use Centros Manager.
1.
Go to: www.radiodetection.com/centrosmanager.
2.
Click on the link to download Centros Manager and a File Download Window will
appear. You will have a choice of either, Run or Save.
Run: Centros Manager will automatically install.
Save: you will be given the option to save Centros Manager to a destination of your
choice. Once you select the destination, the Centros Manager executable program
will download to that destination. Once completed you will have the option to Run
or Open Folder. At this stage Centros Manager has not been installed so you can
either select Run and Centros Manager will automatically install, or you can choose
to Open Folder. When you open the folder the Centros Manager executable file will
be available. To install double click on this file.
.
When Centros Manager is installed run from the Windows Start menu under
Programs or alternatively, use the Centros Manager shortcut on your desk top if
you have opted to have this during installation of Centros Manager.
Note: Once Centros Manager is open, click on Help to open the Centros Manager
Operation Manual.
1