Troubleshooting
The minibar is set by default to a cooling temperature of 7 °C (47 °F) at an ambient
temperature of 25 °C (77 °F).
You can use the setting button (fig. 3 4, page 4) to set the cooling temperature to
one of three values: 5 °C, 12 °C and 7 °C (41 °F, 54 °F and 45 °F).
Thereby the temperature will be changed in the order 5 °C ... 12 °C ... 7 °C ... 5 °C
(41 °F ... 54 °F ... 45 °F ... 41 °F) etc.
➤ Press the setting button (fig. 3 4, page 4) and keep it pressed for 5 s, until the
lamp (fig. 3 1, page 4) starts to blink.
➤ Press immediately the setting button (fig. 3 4, page 4) again.
✓ The lamp (fig. 3 1, page 4) indicates the setting temperature:
– 5 °C (41 °F): the lamp flashes five times in three intervals
– 12 °C (54 °F): the lamp flashes once in three intervals
– 7 °C ( 45 °F): the lamp flashes three times in three intervals
I
NOTE
The minibar sets the cooling temperature automatically to 7 °C (47 °F),
when it is connected to a power source.
8
Troubleshooting
Fault
Device does not
function, Status LED
does not glow.
The device does not
cool (plug is inserted,
Status LED glows).
The Error LED flashes
once per second.
The Error LED flashes
twice per second.
Device does not cool
sufficiently, Status LED
glows, Error LED does
not glow.
20
Possible cause
No voltage present in
the AC voltage socket.
The mains adapter is
defective.
The cooling element is
defective.
Temperature sensor is
defective.
The fan is defective.
The cooling element is
defective.
Poor ventilation
Suggested remedy
Try using another plug socket.
Contact service agent.
Contact service agent.
Contact service agent.
Contact service agent.
Contact service agent.
Check the ventilation.
Clean the filter underneath the device.
DM20
EN