Power consumption of the kiln (0.0/999.9 – Kwatt/h):
P- 15
This parameter defi nes the power of the plant. If the value has been
entered, press the key STEP after cycle end to visualize the power
consumption Kwatt/h for the last cycle. The value gets lost when the
controller is switched off .
16
Function WAITING (0/9999 minutes):
P- 16
This parameter allows to set a fi xed waiting time in case that setpoint
value is not reached. If parameter is set to zero, the function is desabled.
17
Function RECOVERY:
P- 17
Recovery of interrupted cycle and fi ring prosecution after a black-out.
0
Recovery excluded
1
Recovery enabled
11
A1 output alarm intervention modes
Band alarm (setpoint-process)
PROCESS
SETPOINT
HYSTERESIS
A1
ON
OFF
Deviation alarm (setpoint-process)
COMPARISION VALUE
P-13
PROCESS
SETPOINT
HYSTERESIS
A1
ON
OFF
18
- ATR 900/901 User manual
COMPARISON VALUE
P-13
HYSTERESIS
TIME
TIME
The alarm can be:
• working outside
• working inside
HISTÉRESIS
Example: Outside
NB: Alarm treshold is set on
A1
Hysteresis is fi xed as 1°C/°F.
ON
OFF
UMBRAL DE ALARMA
P-13
• Upper deviation
SETPOINT
• Lower deviation
HISTÉRESIS
Example: Upper deviation.
NB: Hysteresis is fi xed as 1°C/°F.
A1
ON
OFF
UMBRAL DE ALARMA
P-13
PROCESO
SETPOINT
HISTÉRESIS
P- 13
.
TIEMPO
PROCESO
TIEMPO