Test For Gas Leaks; Complete The Installation - Bosch HDI8054C Instrucciones De Instalación

Ocultar thumbs Ver también para HDI8054C:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Rigid Pipe Connector Method
If using a flexible connector, return to "Flexible Connector
Method".
The configuration of the rigid pipe connection will vary
depending on the location of the gas pipe stub.
Gas Flow to Range
D
E
B
C
B
A
Item
Elbow; connect to regulator here
A
Pipe Nipple
B
Union
C
Elbow
D
Gas Shutoff Valve
E
F
½" to ¾" Gas Pipe
Complete Gas Connection
Connect pipe to range at the union. Access the connection
through the access panel behind the drawer.
The gas connection is complete. It is important to test for
gas leaks before proceeding with the remainder of the
installation.
9001126426 Rev A
D
B
F

Test for Gas Leaks

9 WARNING
Never check for gas leaks with a flame.
Leak testing is to be conducted by the installer according to
the instructions given in this section.
Note: Be careful not to apply pressure to warming
drawer element during rigid pipe testing.
1. Turn on gas.
2. Apply a non-corrosive leak detection fluid. Include all
joints and fittings between the shutoff valve and the
range. Include gas fittings and joints in the range if con-
nections may have been disturbed during installation.
3. Inspect for leaks. Bubbles appearing around fittings
and connections indicate a leak.
4. If a leak appears, turn off supply line gas shutoff valve
and tighten connections.
5. Retest for leaks. Turn gas back on at supply line shutoff
valve and reapply leak detection fluid.
6. When no bubbles appear, test is complete. Wipe off all
detection fluid residue.
Do not continue to the next step until all leaks are
eliminated.

Complete the installation

Adjust Leveling Legs
1. Make sure that the circuit breaker is off and then plug
range cord into the electrical outlet.
2. Line up range in front of opening.
3. Measure (A) back left corner of opening from floor to
the top of the countertop.
English 15

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Hdi8054uHdip054cHdip054uHgi8054ucHgip054uc

Tabla de contenido