Electrical Outlet and Gas Connection
Location
Dual Fuel models: A flush mount 208/240 VAC dedicated
circuit outlet is required. Use the diagram below to make
sure your installation is properly prepared for the range.
Note the available space for the electrical outlet is shown in
the gray box (DF E) in the illustration following.
The gas connection is accessed by removing the warming
drawer. The available space for the gas connection is
shown in the gray box (G) in the illustration
following.
Gas Models: The power cord and outlet are 120 VAC. Use
the diagram below to make sure your installation area is
properly prepared for the range. Note the available space
for the electrical outlet (flush mount) is shown in the gray
stripped box (Gas E) in the illustration following.
The gas connection is accessed by removing the warming
drawer. The available space for the gas connection is
shown in box G in the following illustration.
9001126426 Rev A

Cabinet Requirements

This unit is designed for installation near adjacent walls and
projecting surfaces constructed of combustible materials.
Prepare the countertop and cabinets.
Allow a minimum of 30" (762 mm) between cabinets
where range is to be installed. No side clearance is
required. Height is set by adjusting the range legs (see
later section, "Complete the installation" on
page 15").
Note: The slide-in range can also replace a
freestanding range. In this case, verify that the opening is
at least 30" (762 mm).

Install Ventilation

Bosch strongly recommends the installation of a ventilation
hood above this range. For most kitchens, a certified hood
rating of not less than 300 CFM is recommended. The
range hood must be installed according to instructions
furnished with the hood.