The numerical fields above have the following meaning:
XX
Hex number whose bits X
Bits
Active
Should be always 0 in normal operation.
X
7
ACTION: Not required.
Should be always 0 in normal operation.
X
6
ACTION: Not required.
HP TS buffer full.
In master mode these bits are asserted when the input HP TS bit rate
X
1
5
is greater than the useful bit rate for the DVB-T/H mode in use.
ACTION: Reduce the peak or average bit rate to avoid overflow.
LP TS buffer full.
X
1
Same as right above but for the LP TS.
4
ACTION: See above.
HP TS sync loss.
In master mode when this bit is 1, a loss of synchronisation with the
X
1
HP transport stream has occurred (2 or more corrupted or missing TS
3
SYNC bytes).
ACTION: Check the availability and compliance of the TS input.
LP TS sync loss.
X
1
Same as right above but for the LP TS.
2
ACTION: See above.
TS sync loss.
In MFN slave mode an assertion of this bit indicates a loss of
X
1
synchronisation with the input transport stream (2 or more corrupted
1
or missing TS SYNC byte).
ACTION: Check the availability and compliance of the TS input.
Valid TS rate.
In MFN slave mode this bit should be 1 in normal operation. When it
is 0 it tells us that the packet rate of the input transport stream is not
within approximately 100ppm of the useful bit rate for the DVB-T/H
X
0
0
parameters currently being used and thus the modulator is incapable
of acquiring lock.
ACTION: Check that the input bit rate is within ±0.1‰ of the nominal
value given in the DVB-T/H specification.