4.15.3 Error messages on the top menu level

Apart from the 16 error messages found in the STATUS menu, the MO-16X also
outputs several error messages on the LCD display. These messages are shown for the
complete duration of the error event and typically require immediate attention from the
user.
The following table shows all the error messages that the MO-16X can display
together with an explanation of what each message means.
Message
MODULATOR ERROR
TS BUFFER FULL
TS SYNC LOST
INVALID TS RATE
04/2008
Generic error which usually implies circuitry malfunction
Input TS bit rate too high leading to overflow in the input
buffer
The modulator has lost sync with the transport stream
input
In MFN slave mode the input bit rate is not adequate
Meaning