Electrical Connections; Control Box - Astralpool pH Pure Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 13
Install the probe vertically with the cable connection uppermost.
Important: place the probe in such a way that the two protective edges of the glass ball are perpendicular
to the flow.
Keep the probe's protective cap for winter storage (with its preservation product or pool water if this is
not possible).
B/ On the salt chlorinator ionization chamber
Mount the pH probe on the salt chlorinator ionization chamber at the designated place.
Important: check that the end of the probe does not protrude directly into the flow. Place it slightly set
back, as indicated on the drawing.
FLOW SWITCH
or
CHLORINE PROBE
Reagent tank
It is preferable to use liquid pH+ or pH- reagents as the case may be. We strongly advise against using
pH correctors in powder form or hydrochloric acid.
Place the reagent tank near to the control box and, if possible, avoid placing it directly underneath. The
end of the suction pipe with its counterweight should be located approximately 5 cm above the bottom
of the tank.
Injector
A/ On the collar unit
The injector rod should be located on the return circuit after the probe and any other equipment (heater,
salt chlorinator, booster...)
B/ On the salt chlorinator ionization chamber
Place the injector rod on the salt chlorinator ionization chamber in the dedicated housing.

Control box

It is essential that the system be operating at the same time as the filter unit.
Probe cable
Connect the BNC plug in the socket located on the right-hand side of the box.
FLOW
GROUND PLUG
ELECTRODE

ELECTRICAL CONNECTIONS

pH PROBE
pH INJECTION
8
FLOW

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

66674

Tabla de contenido