Step 2: Charge the Battery Pack

For Li-Ion batteries:
The batteries must be charged prior to using for the first time
because it is delivered with an energy content as low as possible.
The permissible temperature range for charging is between 0°C to
+40°C /+32°F to +104°F. For optimal charging we recommend
charging the batteries at a low ambient temperature of +10°C to
+20°C/+50°F to +68°F if possible.
It is normal for the battery to become warm during charging. Using
the chargers recommended by Leica Geosystems, it is not possible to
charge the battery if the temperature is too high.
For new batteries or batteries that have been stored for a long time
(> three months), it is effectual to make only one charge/discharge
cycle.
For Li-Ion batteries, a single discharging and charging cycle is
sufficient. We recommend carrying out the process when the battery
capacity indicated on the charger or on a Leica Geosystems product
deviates significantly form the actual battery capacity available.
The batteries can be operated from -30°C to +50°C / -22°F to
+122°F.
Low operating temperatures reduce the capacity that can be drawn;
very high operating temperatures reduce the service life of the
battery.
1
2
DX10_03
Step
Description
1.
Mount the plug onto the wall charger (if it is not already
assembled).
2.
Plug the wall charger into an outlet.
3.
Plug the other end of the wall charger into the DC jack of the
Field PC.
4.
The device turns on after a few seconds, and a flashing red
light signals the device is charging.
6h
4
3
DX10
3
13