the range above the cooking surface, a Thermador
Low Back or Pot and Pan Shelf must be installed. (See
Figure 2). When clearance to combustible material
is over 12", a Thermador Flush Island Trim may be
used. Figure 2 indicates the space required for each
type of backguard.
6. Always keep appliance area clear and free from
combustible materials, gasoline and other flammable
vapors and liquids.
30" minimum from bottom of
overhead Hood to cooking
surface (36" min. if hood
contains combustible
18"
materials
Min.
*35-7/8" Min. Range Height
with Leveling Legs fully
retracted
*36-3/4" Max. Range Height
with Leveling Legs fully
extended.
Δ
For 30" Ranges
}
For 36" Ranges
}
For 48" Ranges
}
Min. Distance Between Overhead Cabinets
of Combustible Material
30" Range – 30"
36" Range – 36"
48" Range – 48"
Range width
)
30", 36" or 48"
For Electrical and Gas Supply Zone, see
Figure 3A.
as defined in the "National Fuel Gas Code" (ANSI Z223.1,
Current Edition).*The range height is adjustable. The level
of the range top must be at the same level or above the
countertop level.
7. Do not obstruct the flow of combustion and ventilation
air to the unit.
8. A five (5) inch minimum clearance is needed when the
range is installed beside a combustible side wall.
Δ
A
s defined in the "National Fuel Gas Code" (ANSI
Z223.1, Current Edition).
30" or 36" Wide Hood
36" or 42" for Island
36" or 42" Wide Hood
42" or 48" for Island
48", 54" or 60" Wide Hood
54" for Island
13" Max.
}
Cabinet
Depth
5" Min. to
combustible
side wall
material ,
(both sides)
Cooking
Surface
,
CAUTION:
See Figure 2
36" Min. to
combustible
,
material
Ð
from cooking
surface
Figure 1: Cabinet Clearances
English 5