4.6. Troubleshooting Chart
In the case of problems not mentioned or problems that you can not solve, contact our
PECOL Technical Assistance Service (page 70).
PROBLEM
The power tool will not start
Low performance of the power
tool
Percussion is not performed
Irregular operation (stop - start
- stop ...)
P.68
PT
ES
POSSIBLE CAUSE
Power failure.
Worn carbon brushes.
The circuit breaker on the power
supply board was started.
Switch damaged.
Inadequate electrical extension.
Electric extension coiled.
The internal and pneumatic
system lubrication are deficient.
Inadequate electrical network.
The machine is too cold.
Power tool wires or an extension
cable (if applicable) broken.
EN
FR
SOLUTION
Connect other electrical equipment to
the plug and check if it works.
Refer to PECOL Technical Service
to replace the brushes.
Check if the cause is any short circuit.
Refer to PECOL Technical Assistance
Service.
Check the total permissible power of
the extension. Use a wired extension
of larger diametre (section), which
supports the required power.
If it is a winding extension, it loses
power when it is coiled. Uncoil.
See pages 67.
Check if the voltage, frequency and
type of the mains is suitable for the
power tool.
If you are using a generator or
transformer, an output power of
at least twice than required for
the power tool and a rated voltage
variation of at most 5% and at least
15% is recommended.
Set the drill hammer to idle until
sufficient heating is achieved and
percussion returns.
If the power cable of the power tool is
damaged, it must be replaced. If it is a
defective extension, replace it.