10.2. Connecting to vehicle power
source
Make sure no other energy source is connected (gas,
230V).
A safety fuse must be installed in the electricity supply
between battery and the cooling box in a duct.
12V appliances must be connected to a vehicle
cigarette lighter, which is protected with a 10A fuse.
24V appliances must be connected by inserting a
terminal block and switch and protected with a 5A
fuse. The switch must be suitable for switching a 5A
current.
It is not necessary to consider the polarity when
connecting the unit.
In case you need a longer cable, please refer to the
table below:
Cable cross section
2.5 mm
until
2
4.0 mm
until
2
6.0 mm
until
2
Do not connect a cable thicker than 2.5 mm
cigarette lighter plug! Please build a terminal block
connection.
For your safety:
Do not check for leaks with a naked flame!
11. Environmental protection
information
Ammonia (natural hydrogen and nitrogen compound) is
used as refrigerant agent in the cooling unit.
The ozone-friendly cyclopentane is used as a blowing
agent for the PU foam insulation.
Sodium chromate is used for corrosion protection (less
than 2 weight % of the coolant).

12. Recycling

After unpacking the appliance, the packing materials
should be delivered to a local collection site. At the end of
its useful lifetime, the appliance should be delivered to a
specialised recycling firm, which reclaims the usable
materials. The rest is properly destroyed.
max. cable lengths
12 V
24 V
2.5 m
5 m
4.0 m
8 m
6.0 m
12 m
into the
2
10.3. Connection and replacement of
the gas cartridge
The correct connection of the fridge has to be
carried out by a skilled specialist. Note the
particularly valid national rules for usage of
liqiud gas driven appliances.
Make sure no other energy source is connected
(230V, 12V).
The unit must not be connected to town or
natural gas pipelines. It is suitable for use with self
sealing gas cartridge (250g).
Before connecting the gas cartridge, please read
the handling and storage instructions provided on
the side of the cartridge. Check the proper fitting of
the gas cartridge to the connecting port of the
appliance. Before connecting the gas cartridge,
check the cleanliness of the connecting port of the
appliance to the gas cartridge.
Perform this operation in a well-ventilated area, free
from ignition sources. Close the appliance valve.
Put the lever on upper position. Place the cartridge
in the appliance.
While transporting and handling the appliance, the
gas cartridge may not be connected to the
appliance.
Do not smoke while checking for leaks!
Appliances bearing this symbol must be
deposited at the designated local reception
point for the disposal of electrical and
electronic equipment.
It is not permitted that this product be
disposed of by way of the normal
household refuse collection system.
Dometic refrigerators bear this symbol on the
specifications plate (data plate) to be found on the rear
cover of the unit.
This appliance complies with the following EEC
directives:
LVD-Directive
2006/95/EC
EMC-Directive
2004/108/EC
Gas-Directive
90/396/EEC
CE-Directive
93/68/EEC
RoHS-Directive
2002/95/EC
WEEE-Directive
2002/96/EC.
GB