Section 2. General Description; Introduction; Description; Section 3. Installation Information - Zodiac Jandy Pro Serie Manual De Instalación Y Operación

Ocultar thumbs Ver también para Jandy Pro Serie:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Jandy
Pro Series ePump™ Series Pump | Installation and Operation Manual
®

Section 2. General Description

2.1

Introduction

This manual contains information for the proper
installation, operation, and maintenance of Jandy
Pro Series ePump Series variable-speed pumps.
Procedures in this manual must be followed exactly.
To obtain additional copies of this manual, contact
Zodiac
Customer Support at 800.822.7933 or visit our
®
website at www.zodiacpoolsystems.com. For address
information, see the back cover of this manual.
2.2

Description

The ePump is a variable-speed pump that can be
run from 600 RPM to 3450 RPM. When connected to
the Jandy Pro Series ePump controller, up to eight (8)
speed settings may be programmed and recalled. This
allows you to select the most appropriate speed for
your application. Even more versatile programming is
possible when you use a Jandy Pro Series AquaLink
RS controller.
The Jandy Pro Series ePump is designed to meet
the needs of today's more hydraulically demanding
pool equipment. The pump housing, backplate, diffuser,
impeller, and hair and lint pot (pump debris filter
basket) are all made from high quality thermoplastic
materials. These materials were chosen for their strength
and corrosion resistance.
The pump is driven by an electric motor directly
attached to the pump impeller. As the electric motor
turns, it causes the impeller to turn, which forces water
to flow through the pump. The water flows through the
pump inlet and then into the filter basket. The basket
assembly pre-strains/traps large particles. The water
then enters the center of the pump housing, flows
through the impeller into the diffuser, and flows out the
pump discharge port.

Section 3. Installation Information

3.1

Plumbing

3.1.1 Preparation Information

1.
Upon receipt of the pump, check the carton for
damage. Open the carton and check the pump for
concealed damage, such as cracks, dents or a bent
base. If damage is found, contact the shipper or
distributor where the pump was purchased.
2.
Inspect the contents of the carton and verify
that all parts are included. See Section 7.1,
Replacement Parts List and Exploded View.

3.1.2 Pump Location

For Canadian installation, this pump carries a Type
3R enclosure rating and therefore is not intended for
installation in areas subjected to windblown dust.
1.
Zodiac recommends installing the pump within
one (1) foot above water level. Refer to Figure
2 for a typical installation. The pump should not
be elevated more than a few feet above the water
level of the pool. A check valve is recommended
on the suction line to the pump.
Some Safety Vacuum Release System (SVRS)
devices are not compatible with the installation of
check valves. If the pool has an SVRS device, be
sure to confirm that it will continue to safely operate
when any check valves are installed.
®
NOTE To achieve better self-priming, install the
pump as close as possible to the water level
of the pool.
2.
If the pump is located below water level, isolation
valves must be installed on both the suction and
return lines to prevent back flow of pool water
during any routine or required servicing.
3.
The pump and other circulation equipment must
be located more than five (5) feet from the water.
Choose a location that will minimize turns in the
piping.
NOTE In Canada, the pump must be located a
minimum of three (3) meters (approximately 10
feet) from the water (CSA C22.1).
4.
The pump must be placed on a solid foundation
that will not vibrate. To further reduce the
possibility of vibration noise, bolt the pump to the
foundation, or place it on a rubber mat.
NOTE Zodiac Pool Systems, Inc. recommends bolting
the pump directly to the foundation.
5.
The pump foundation must have adequate drainage
to prevent the motor from getting wet. Protect the
pump from the rain and sun.
6.
Proper ventilation is required for the pump to
operate normally. All motors generate heat that
must be removed by providing proper ventilation.
7.
Provide access for future services by leaving a
clear area around the pump. Allow plenty of space
above the pump to remove the lid and basket for
cleaning.
8.
If the equipment is in a potentially dark area,
provide adequate lighting.
ENGLISH
Page 7
CAUTION
WARNING

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Jandy epump serieJandy jep2.0Jandy jep1.5

Tabla de contenido