Pro Series ePump™ Series Pump | Installation and Operation Manual
®
can be a drain and skimmer, two (2) drains, two
(2) skimmers, or a skimmer with an equalizer line
installed. For additional details and guidelines,
refer to ANSI/APSP 7, the standard for Suction
Entrapment Avoidance in Swimming Pools,
Wading Pools, Spas, Hot Tubs, and Catch Basins.
Check the local codes for proper installation
requirements. Applicable local codes will take
precedence over other codes.
NOTE To prevent entrapment, the system must be
built so it cannot operate with the pump drawing
water from only one (1) main drain. At least two
(2) main drains must be connected to the pump
when it is in operation. However, if two (2) main
drains run into a single suction line, the single
suction line may be equipped with a valve that
will shut off both main drains from the pump.
5.
The piping must be well supported and not forced
together where it will experience constant stress.
6.
Always use properly sized valves. Jandy Pro
Series Diverter Valves and Jandy Pro Series Ball
Valves typically have the best flow capabilities.
7.
Use the fewest fittings possible. Each additional
fitting has the effect of moving the equipment
farther away from the water.
NOTE If more than ten suction fittings are needed, the
pipe size must be increased.
8.
Every new installation must be pressure tested
according to local codes.
3.2

Electrical Installation

3.2.1 Voltage Checks

The correct voltage, as specified on the pump data
plate, is necessary for proper performance and long
motor life. Incorrect voltage will decrease the pump's
ability to perform and could cause overheating, reduce
the motor life, and result in higher electric bills.
Table 2. Recommended Wire Size and Maximum Overcurrent for ePumps
MAXIMUM WIRE SIZE AND MAXIMUM OVERCURRENT PROTECTION FOR ePUMP SERIES PUMPS*
Distance from Sub-panel
Model
JEP2.0, Regal Beloit Motor
JEP1.5, Regal Beloit Motor
*Assumes three (3) copper conductors in a buried conduit and 3% maximum voltage loss in branch circuit. All National Electrical Code
(NEC
) and local codes must be followed. Table shows minimum wire size and branch fuse recommendations for typical installation per
®
NEC.
Inverse - Time Circuit Breaker or Branch
Fuse AMPS
Class:CC, G, H, J, K, RK, or T
230 VAC
20A Max
20A Max
It is the responsibility of the electrical installer to
provide data plate operating voltage to the pump by
ensuring proper circuit sizes and wire sizes for this
specific application.
CAUTION
Failure to provide data plate voltage (within 10%)
during operation will cause the motor to overheat
and void the warranty.

3.2.2 Bonding

1.
The motor frame must be bonded to a reliable
grounding point using a solid copper conductor,
No. 8 AWG or larger. In Canada, No. 6 AWG or
larger must be used. If the pump is installed within
five (5) feet (1.5 m) of the inside walls of the
swimming pool, spa, or hot tub, the motor frame
must be bonded to all metal parts of the swimming
pool, spa, or hot tub structure and to all electrical
equipment, metal conduit, and metal piping within
five (5) feet (1.5 m) of the inside walls of the
swimming pool, spa, or hot tub.
2.
Bond the motor using the provided external lug.
See Figure 3.
WARNING
Always disconnect the power source before working
on a motor or its connected load.
WARNING
In order to avoid the risk of property damage,
severe personal injury, and/or death, make sure
that the control switch, time clock, or control system
is installed in an accessible location, so that in the
event of an equipment failure or a loose plumbing
fitting, the equipment can be easily turned off.
CAUTION
The pump must be permanently connected to a
dedicated electrical circuit. No other equipment,
lights, appliances, or outlets may be connected to the
pump circuit, with the exception of devices that may
be required to operate simultaneously with the pump,
such as a chlorinating device or heater.
0 - 150 Feet (0-45 meters)
ENGLISH
Page 9
Voltage
208-230 VAC
12
12
®