Gewiss JOINON Serie Manual De Instalacion Y Uso página 69

Ocultar thumbs Ver también para JOINON Serie:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 113
Faults and troubleshooting
Code
Error description
Error in the control of the socket-
Error 6
outlet locking motor (it does not
shift from OPEN to CLOSED)
Error in the control of the socket-
Error 7
outlet locking motor (it does not
shift from CLOSED to OPEN)
The energy meters are no longer
Error 8
communicating with the elec-
tronic card
7.55.4.502.0 - Installation and Operation Manual
Solution
Manually check the mobility
of the pin by moving the red
lever on the back of the type 2
socket-outlet locking motor.
Manually check the mobility
of the pin by moving the red
lever on the back of the type 2
socket-outlet locking motor.
Check the connection of the
Modbus line.
Check the power supply to the
energy meters.
Check the energy meters are
working properly.
Check the correct numbering of
the component on the Modbus
line.
Gewiss
Position
69
IT
EN
FR
ES
DE
RO
HU
NL

Publicidad

Tabla de contenido
loading

Tabla de contenido