Modifying The Operating Parameters Of The Recharging Station - Gewiss JOINON Serie Manual De Instalacion Y Uso

Ocultar thumbs Ver también para JOINON Serie:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 113
Gewiss

13. Modifying the operating parameters of the recharging station

Even after installing the product, you can still modify certain station operating parameters by means of a text file to be saved in the
micro SD card inserted in the recharging station itself.
Create a text file on your computer and rename it "config.ini". Insert the parameters you want to alter in this file. The addition of
parameters must follow the indications given below.
The parameters that can be modified are:
Function
Name of the
description
parameter to be
used
Language
LANGUAGE
Maximum input
MAXAMPERAVAILABLE
current
Maximum current
AMPERSOCKET
per socket-outlet
Date
DATETIME
Log level
LOGLEVEL
72
Options available and examples
By default, the station is set with the Italian language. The language can be changed using the
LANGUAGE parameter. The languages that can be set, and the parameters to be used, are:
EN= English
FR= French
DE= German
ES= Spanish
IT= Italian
RO= Romanian
HU= Hungarian
Example
LANGUAGE=IT
or
LANGUAGE=EN
You can set an input current other than the one set in the factory, to suit the real availability and
avoid problems during recharging. To do this, use the MAXAMPERAVAILABLE parameter
Example
MAXAMPERAVAILABLE=64
You can set a recharging current for each socket-outlet other than the one set in the factory, to suit
the real availability (e.g. if the maximum input current value is changed) and avoid problems during
recharging. To do this, use the AMPERSOCKET1 and/or AMPERSOCKET2 parameter
Example
AMPERSOCKET1=32
AMPERSOCKET2=16
If the date on the recharging station is not correct, you can change it using the DATETIME parameter.
The format is YYYY/MM/DD-hh:mm
Example
DATETIME=2019/08/15-14:30
The LOG level saved by the recharging station on the micro SD card can be altered via the LOGLEVEL
parameter. You can choose one of 5 levels, from 0 (limited verbosity) to 4 (high verbosity)
Example
LOGLEVEL=1
Modifying the operating parameters of the recharging station
7.55.4.502.0 - Installation and Operation Manual

Publicidad

Tabla de contenido
loading

Tabla de contenido