13 – Configuration menu
The Baby T ZERO and Baby T PLUS models have two independent displays above the
group button pad with which you can control the following parameters:
Parameter
t
tc
tec
P/I/d/b
ce
teE
tiE
Ud
Px
Cr
u
Ac
EP
SP
ST
20
MANUAL BABY T ENG-ESP_DE 2020 .indd 20
MANUAL BABY T ENG-ESP_DE 2020 .indd 20
Description
Set point temperature of the coffee group, shown on the left screen
during the operation of the machine.
Temperature of the steam boiler
Sub-menu with temperature control configuration parameters,
including P / I / d / b / Ce
Configuration parameters of the PID temperature control.
Power configuration parameter. Depending on this parameter (number
between 1 and 3) we indicate to the machine how many elements can
work at the same time, always prioritizing those of the coffee groups.
See power limitation table to see the different options in section 5 -
electrical connection.
Steam boiler's temperature in stand-by mode
Inactivity time after which the temperature of the steam boiler is set
to the stand-by one (TeE parameter). If this value is set to 0, stand-by
function is deactivated.
Units of measure: Degrees Celsius (C) or Farenheit (F)
Pre-infusion of the selection x (x = 1,2,3,4) of the button, configurable
between 0 and 5 seconds. For example, P1 is the pre-infusion time
(pump ON) of selection 1. Pump time OFF is always 3s. Selection
5 (XL, continuous delivery) does not have pre-infusion time. Note:
Options P1 and P2 correspond to the normal functions of the S and
L keys respectively, while the P3 and P4 options correspond to the
double function of the S and L keys respectively.
Stopwatch activated or deactivated. When activated, it is displayed on
the right screen during the operation of the machine.
Temperature correction parameter; this allows an offset to be
introduced between the actual temperature and the one shown on the
group's display.
Steam boiler activated / deactivated
Allows the hydraulic connection to be configured as MAINS (red) or
RESERVOIR (dep).
Indicates the number of partial services (since the last reset to 0).
Note: This option counts the number of coffees made, not the number
of times the keys are pressed, so the double selection will count as
two coffees.
Indicates the number of total services of the machine.