CONNECTION:
There are three types of connection depending on a facility's characteristics:
1. Connection with a manual valve (code 07444). To connect the filter using
a manual valve, first remove the four upper screws and the pressure gauge
so that the PCB can be accessed. In order to connect the filter to the power
supply and use the manual valve, you must remove the cable gland from
the connection not used and replace it with the IP68 cap supplied with the
filter. The other cable gland will be used to run the power cable through it
that must be connected to the switchboard's terminal block and suitably
protected using a residual-current device (30 mA) and a thermal magnetic
circuit breaker sized according to the characteristics of the installation and
the regulations that apply in your country.
To enable it, place your finger on the touch panel for a maximum of 20 se-
conds, following which it will switch off automatically.
If you prefer, you can press the button twice and the filter will automatically
turn for 40 seconds. If you wish to stop it from working before the 40 seconds
are up, press the button twice once again.
2. Connection with an automatic valve (code 57187). To connect the filter using an automatic valve, first
remove the upper four screws and the pressure gauge so that the PCB can be accessed. Connect the cables as
shown in the drawing (using a screwdriver, tighten the tab so that the cable can be threaded through or out of
the hole). The connection to the valve should be parallel to the electrovalve's drainage signal (5 - 24 V AC/DC
self-limited to 20 mA). The power connection should be done as described in the previous section.
Motor
User
interface
flat cable
3. Connection to AstralPool MAC. To connect the filter to AstralPool MAC,
first turn off the power of all units and remove the four screws from the
upper lid and the pressure gauge so that the PCB can be accessed. Connect
the cables as shown in the drawing (using a screwdriver, tighten the tab so
that the cable can be threaded through or out of the hole). The connection
to AstralPool MAC should be parallel to electrovalve's drainage (EV DRAIN).
To carry out this by-pass, it is preferable to use the APMac Connection Kit
(ask your dealer for details). The power supply should NOT run through the
APMac, but through the switchboard instead using suitably protected wiring
as described above in this manual.
IMPORTANTE:
• The multiple disconnection device must be used with a separation of at least 3 mm between contacts in order
to disconnect the power pack.
• Use a rigid cable as a network connection. If a flexible cable is used for the network connection, terminals must
be used for connecting it to the terminals of the unit's electric circuit.
• The unit should be connected to a socket (see the unit's characteristics on the label) with an earth connection,
protected by a residual-current device (RCD) with a residual working current set to no more than 30 mA.
• Check that the unit's earth cable is properly placed and connected.
• Ensure that the installation and electrical connections are fit for purpose, otherwise the unit's manufacturer will
decline all liability and consider the warranty to be invalid.
• There may be special regulations for the installation.
• Danger of electrocution in the event of an unsuitable network connection.
• The network cable must be connected by a qualified and authorised expert.
• For 230 V use an H07 RN-F3 type power cable and adapt the section of the unit's power cable and its length.
NanoFiber
L
N
Valve
Power supply
220-240V
50/60 Hz
Automatic valve
6
NanoFiber
Motor
User
interface
flat cable
elect valv
Valve
(EV Drain)
NanoFiber
Motor
AstralPool Mac
User
interface
flat cable
Distribu-
tion panel
220-240V
50/60 Hz
L
N
Power supply
220-240V
50/60 Hz
L
N
Power supply
220-240V
50/60 Hz