2. 1 2
ASSEMBLING THE GAS
ASSEMBLY
Connect the gas assembly to the burner
manifold as shown in fig. 12.
The gas assembly may be assembled on
the right or left side of the manifold.
WARNING: in case of the gas assembly is
mounted on the left side of the manifold,
remove and rotate the gas valve of 180°
to get access frontally at the regulations.
2. 1 3
ASSEMBLING THE CONTROL
PANEL (fig. 12/a)
Remove the control panel's protective
cover and insert the wiring guard on the
front upper panel, anchoring it in place with
the screws provided. Replace the cover.
Proceed to assemble the instrument panel,
anchoring it in place with the screws provi-
ded. Insert the instrument bulbs in their
sheaths: first insert the control thermostat
bulb, pushing it in until it touches the bot-
tom of the sheath.
WARNING: To ensure correct temperatu-
re control in the boiler, the bulbs of the
control and safety devices must be inser-
ted in the sheath from the side corre-
sponding to the heating system delivery
and return connections. If the heating
system delivery and return connections
are on the left side of the generator, the
gas assembly must also be assembled on
the left side to permit this arrangement.
2. 1 4
ASSEMBLING THE

ELECTRICAL PANEL

(fig. 12/b)
Remove the cover of the electrical panel
and anchor the control panel to the lower
front wall using the screws provided.
Connect the two sockets to the plugs from
the control panel. Complete the electrical
panel by hooking up the gas valve, the
second gas solenoid valve, the gas pressu-
re switch and the coil. Unwind the cables of
the ignition and detection electrodes emer-
ging from the electrical panel. Insert the
ignition electrode in the hole between the
head and the intermediate on the gas
assembly side, anchoring it to the two stud
bolts (fig. 12/c).
Perform the same operation on the detec-
tion electrode, which will go in the hole pro-
vided between the head and the interme-
diary at the other end of the body.
NOTE: When assembling the two electro-
des, be very careful not to break their
ceramic coating; they must be replaced
immediately if it is broken. All gas connec-
tions must be t est ed for seal af t er
assembly using soapy water or products
manufactured specifically for the purpo-
se, without using open flame.
60
KEY
1 Burner manifold
2 Gas assembly
3 Bulb sheath
KEY
1 Ignition electrode
2 M5 x 15 stud bolt
3 Washer ø 5.3
4 Nut M5 OT
5 Right head
6 Intermediate element
with nib
Fig. 12
KEY
1 Protective cover
2 Wiring guard
3 Front upper panel
4 Instrument panel
5 Instrument bulbs
6 Sheath
7 5 pole plug
8 7 pole plug
Fig. 12/a
KEY
1 Cover
2 Electrical panel
3 Lower front panel
4 5 pole plug
5 7 pole plug
6 Second gas solenoid valve cable
7 Gas pressure switch cable
8 Gas valve cable
9 Coil cable
10 Detection electrode
11 Ignition electrode
Fig. 12/b