KEY
SB
Boiler shutdown indicator light
PG
Gas pressure switch
EVG Main gas valve
F
T 4 fuse
ER
Detection electrode
E
Ignition electrode
TC
Step control thermostat
IG
Main switch
SG
Gas pressure indicator light
TS
Safety thermostat
A
SM 191. 1 device
P
Water pressure switch (not supplied)
B
Coil
EVS Second gas solenoid valve
F
Interference filter
TF
Smokes thermostat (Poland only)
UA
Type QAA70 room thermometer (optional)
2. 1 5
ELECTRICAL CONNECTION
The electrical power supply must be con-
nected to terminals L and N and to the
panel complying with all phase and neu-
tral positions as shown in the diagram. If
they are not connected properly, the
flame detection circuit will not work and
the boiler will be shut down. The boiler
must be connected up to a single phase
230V-50Hz power supply through a main
switch protected by fuses with at least 3
mm between contacts (fig. 13).
NOTE: The device must be connected to an
efficient grounding system. SIME shall not
accept any liability for damage or injury
resulting from failure to ground the boiler.
Turn off the power supply before perfor-
ming any operations on the electrical panel.
2. 1 6
RVA43.222 CONTROL UNIT
(optional)
All boiler functions can be controlled by the
SE
Outdoor temperature probe (optional)
SC
Type QAZ21 boiler immersion probe (optional)
SS
Type QAZ21 boiler immersion probe (optional)
PI
Heating system pump (not supplied)
PB
Boiler pump (not supplied)
C
RVA 43.222 control unit connectors (black - red - brown)
TA
Room thermostat
TI
Insulation transformer (Belgium only)
F1
Fuse F800 mA (Belgium only)
SF
Flue gas gate (not supplied)
NOTE: When not using the unit to connect up the TA, remove
the jumper from terminals 1-4.
When connecting up the RVA 43.222 unit, remove jumpers
12-13 and 15-16. When connecting up the flue gas gate (SF)
remove the jumper between terminals 22-23.
Connect up the pumps (PB-PI) as shown in the diagram only if
using the RVA 43.222 unit.
optional control unit code 8096303, sup-
plied with an outdoor temperature probe
(SE) and boiler immersion probe (SC) (fig.
14). Use of the control unit requires con-
nection of an additional series of low volta-
ge connectors for connection of probes
and the room temperature control unit
(the connectors are supplied in a bag in the
KEY
1 Plastic hole cover
2 Optional control unit
control panel). The bulb of the sensor of the
external D.H.W. tank (SS), optional code
6277110, must be inserted in the hot
water sheath and the boiler probe (SC) in
the boiler sheath.
To assemble the outdoor temperature
probe (SE), follow the instructions provided
on its packaging.
2
1
Fig. 13
Fig. 14