The average filter cartridge working life varies according to use, environmental conditions, pressure, etc. In general, changes in
water taste, odour and colour indicate that the cartridge requires replacement.
A. Before opening the container, turn off water supply tap and place a container under the system to collect any water that may
spill when the cartridges are removed.
B. Release product pressure by opening a downstream tap.
C. Open the filter housing by unscrewing the bowl from the top.
D. Remove the used cartridge.
E. Gently clean the bowl with cold water and a soft sponge.
F. Remove the protective film from the new cartridge.
G. Insert the new cartridge in the bowl.
H. Lubricate the bowl o-ring with the lubricant included in the package (Lubrikit). If the o-ring appears damaged, replace it with a
new o-ring (o-ring included in the package) and lubricate with Lubrikit.
I. Screw the bowl onto the head and tighten with a wrench, do not over tighten. If the wrench is not included in the package,
purchase it separately.
J. Slowly open the main water tap.
K. Let water flow for about 5 minutes from a tap downstream from the product before use. This also allows air purge of the product.
Using cartridges other than original ones voids the warranty.
3.4 AIC activated carbon post-filter replacement
Remove the blue safety rings from the post-filter quick-fits (input and output).
Press the quick-fits coupling release ring to remove the input and output pipes.
Extract the used post-filter from the bracket and replace it with a new AIC post-filter (only use original spare parts or the
warranty is voided).
Fit the pipes in the input and output, making sure the pipes are securely locked in the quick-fit.
Re-insert the safety rings in the quick-fits.
3.5 AIM re-mineralising post-filter replacement
Perform the replacement steps as in the procedure described in point 3.4.
4.
NON-ROUTINE MAINTENANCE
Non-routine maintenance (repairs and/or replacement of non consumable parts) must be performed by personnel qualified
by the manufacturer and accredited distributors, or the warranty is void.