2.5.3 Storage tank installation
Place the tank near the machine.
Loosen the fastening nut on the tank ball valve.
Insert the 1/4" tank connection pipe and tighten the fastening nut.
Connect the 1/4" pipe to the machine.
2.5.4 Dedicated tap installation
Drill a 12mm diameter hole on the sink bottom (no. 6), remove any burrs with a round file.
Place the gasket (no. 5) with spacer (no. 4) and chrome-plated base (no. 3) on the hole, insert the threaded tap rod
(no. 2).
ON the bottom side, insert in order the gasket (no. 7), elastic washer (no. 8) and screw in the fastening nut (no. 9).
Insert the pipe (no. 12) in the end nut (no. 11) and plastic ring (no. 10).
Tighten the end nut (no. 11) on the threaded tap rod (no. 2).
1
Tap
2
Threaded tap rod
3
Chrome-plated base
4
Spacer
5
Gasket
6
Sink base
7
Gasket
8
Elastic washer
9
Lock nut
10
Plastic ring
11
End nut
12
1/4" permeated pipe
2.5.5 UV lamp, membrane and filter cartridge installation
To avoid potential damages during transport, the UV lamp is usually packaged separately; insert the supplied lamp in
the unit.
To install the lamp, see section 3.1: "UV lamp replacement".
To install the membrane, see paragraph 3.2: "Membrane replacement".
To install the filter cartridge, see paragraph 3.3: "Filter cartridge replacement".
WARNING: using cartridges other than original ones voids the warranty.