ENGLISH
- the value of the proportional constant
- the value of the integrative constant
- the value of the derivative constant
- the value of the offset for group 1
- the value of the offset for group 2
- the value of the offset for group 3
To enter this phase you must supply power to the system by holding down simultaneously the buttons
K+/ONOFF.GR1 and K-/PROG.GR1 on the keyboard of the 1st group.
In this programming operation the button K-/PROG.GR1 scrolls through the menus, while the button K+/ON/OFF.GR1 confirms entry to a menu,
and within the menu both buttons allow you to increase or decrease the parameter.
The parameter is memorised automatically, you just have to wait 2 seconds.
When the display that is showing the modified or non modified parameter shows the parameter again, for example F.0x , it means that it has been
memorised.
F.01 = NUMBER OF HEATING GROUPS
On entering the programming phase, the display of the keyboard of the 1st group immediately shows the first parameter that can be modified which
is the number of usable groups, which may be 1, 2 or 3.
When confirmation is given with K+/ONOFF.GR1 the previously set value of the parameter is shown which may be 3 or 2 or 1. If you want to
change it, use the buttons K+/ONOFF.GR1 and K-/PROG.GR1 and wait 2 seconds for it to be automatically memorised.
F.02 = NUMBER OF KEYBOARDS
Moving on to the next parameter with the button K-/PROG.GR1, it is possible to set the number of keyboards that can be used.
When confirmation is given with K+/ONOFF.GR1 the previously set value of the parameter is shown which may be 3 or 1 (2 is not possible).
If you want to change it, use the buttons K+/ONOFF.GR1 and K-/PROG.GR1 and wait 2 seconds for it to be automatically memorised.
F.03 = DEGREES CELSIUS OR DEGREES FAHRENHEIT
Moving on to the next parameter with the button K-/PROG.GR1, it is possible to set the display in degrees Celsius or Fahrenheit.
When confirmation is given with K+/ONOFF.GR1 the previously set value of the parameter is shown which may be °C or °F .
If you want to change it, use the buttons K+/ONOFF.GR1 and K-/PROG.GR1 and wait 2 seconds for it to be automatically memorised.
P: = PROPORTIONAL CONSTANT OF PID THERMOREGULATION
Moving on to the next parameter with the button K-/PROG.GR1, it is possible to set the value of the proportional constant of PID thermoregulation.
When confirmation is given with K+/ONOFF.GR1 the previously set value of the parameter is shown which may be varied from 0.1 to 99.9 in
steps of 0.1.
If you want to change it, use the buttons K+/ONOFF.GR1 and K-/PROG.GR1 and wait 2 seconds for it to be automatically memorised.
i. = INTEGRATIVE CONSTANT OF PID THERMOREGULATION
Moving on to the next parameter with the button K-/PROG.GR1, it is possible to set the value of the integrative constant of PID thermoregulation.
When confirmation is given with K+/ONOFF.GR1 the previously set value of the parameter is shown which may be varied from 0.1 to 99.9 in steps of 0.1.
If you want to change it, use the buttons K+/ONOFF.GR1 and K-/PROG.GR1 and wait 2 seconds for it to be automatically memorised.
d: = DERIVATIVE CONSTANT OF PID THERMOREGULATION
Moving on to the next parameter with the button K-/PROG.GR1, it is possible to set the value of the derivative constant of PID thermoregulation.
When confirmation is given with K+/ONOFF.GR1 the previously set value of the parameter is shown which may be varied from 0.1 to 99.9 in steps of 0.1.
If you want to change it, use the buttons K+/ONOFF.GR1 and K-/PROG.GR1 and wait 3 seconds for it to be automatically memorised.
F.04 = GROUP 1 OFFSET
Moving on to the next parameter with the button K-/PROG.GR1, it is possible to change the temperature offset for group 1.
When confirmation is given with K+/ONOFF.GR1 the previously set value of the parameter is shown which may be varied from 1 to 30°C in steps of 1°C.
If you want to change it, use the buttons K+/ONOFF.GR1 and K-/PROG.GR1 and wait 2 seconds for it to be automatically memorised.
F.05 = GROUP 2 OFFSET
Moving on to the next parameter with the button K-/PROG.GR1, it is possible to change the temperature offset for group 2.
When confirmation is given with K+/ONOFF.GR1 the previously set value of the parameter is shown which may be varied from 1 to 30°C in steps
of 1°C.
If you want to change it, use the buttons K+/ONOFF.GR1 and K-/PROG.GR1 and wait 2 seconds for it to be automatically memorised.
F.05 = GROUP 3 OFFSET
Moving on to the next parameter with the button K-/PROG.GR1, it is possible to change the temperature offset for group 3.
When confirmation is given with K+/ONOFF.GR1 the previously set value of the parameter is shown which may be varied from 1 to 30°C in steps of 1°C.
If you want to change it, use the buttons K+/ONOFF.GR1 and K-/PROG.GR1 and wait 2 seconds for it to be automatically memorised.
TO LEAVE THE TECHNICAL LEVEL PROGRAMMING PHASE YOU MUST SWITCH THE PIDBULL CONTROL OFF AND ON AGAIN.
parameter on the display P.
parameter on the display i.
parameter on the display d.
parameter on the display F.04
parameter on the display F.05
parameter on the display F.06
69
when switching on