English
NOTE
○ Do not store in a location where children can easily
reach or take out the appliance.
○ Do not store in a damp location or in an area exposed to
rainfall.
○ Do not store in direct sunlight or in a location where
temperatures may suddenly change
○ Do not store in a location with volatile materials that
could ignite or explode.
○ Do not stand the appliance against a wall without using
the strap to fi x it in place. (Fig. 14)
Failure to do so may result in damage from a fall.
CAUTION
In the operation and maintenance of power tools, the
safety regulations and standards prescribed in each
country must be observed.
TROUBLESHOOTING
Use the inspections in the table below if the tool does not operate normally. If this does not remedy the problem, consult
your dealer or the HiKOKI Authorized Service Center.
Symptom
Tool doesn't run
Tool suddenly stopped
Poor suction
Exhaust or the main unit
is hot
Abnormal noise/foul odor
Possible cause
No remaining battery power
Fan clogged with dust, causing overload
The battery is overheated.
Dust case is full.
Nozzle is plugged.
Nozzle or extension pipe is loose.
Nozzle or extension pipe is cracked or
damaged.
Filter is clogged.
The motor is overheating because the
dust case is full, or the fi lter is clogged.
Filter in not properly installed, resulting in
foreign matter getting into the motor.
Important notice on the batteries for the HiKOKI
cordless power tools
Please always use one of our designated genuine
batteries. We cannot guarantee the safety and
performance of our cordless power tool when used
with batteries other than these designated by us, or
when the battery is disassembled and modifi ed (such
as disassembly and replacement of cells or other
internal parts).
GUARANTEE
We guarantee HiKOKI Power Tools in accordance with
statutory/country specifi c regulation. This guarantee does
not cover defects or damage due to misuse, abuse, or
normal wear and tear. In case of complaint, please send
the Power Tool, undismantled, with the GUARANTEE
CERTIFICATE found at the end of this Handling instruction,
to a HiKOKI Authorized Service Center.
Charge the battery.
Contact place of purchase and arrange
for dismantling and cleaning.
Let the battery cool down.
Dispose the dust.
Remove the obstruction.
Firmly tighten the unit.
Exchange the unit with a new one.
Turn the dust case and scrape off dust
with dust removal blade, or remove the
fi lter and lightly strike it or wash with
water.
Dispose the dust. Or else, clean the fi lter.
Remove the dust case, point the intake
port downward and gently shake to
remove foreign matter and dust.
Should abnormal noise/foul odor persist,
the motor may be damaged. Immediately
discontinue use and arrange for repairs.
10
Remedy