Descargar Imprimir esta página

Beninca AU.TR Libro De Instrucciones página 8

Centralita a microprocesador por

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

End of programming
Dip-switch 1÷4= Off/Off/Off/Off
Menu 1
Dip-switch 1÷4= On/Off/Off/Off
Menu 2
Dip-switch 1÷4= Off/On/Off/Off
Dwell time for automatic closure
Dip-switch 1÷4= On/On/Off/Off
If the contact of the input FTC is open,
the dwell time is reset.
Duration of courtesy light
Dip-switch 1÷4= Off/Off/On/Off
The time during which the courtesy light is
on is reset if the contact of the input FTC is
opened and then closed (passage of people
or vehicles) during the dwell time of automa-
tic closure.
Continued ...
8
Function - part 1
End of the programming phase and storage of changes in
ON
memory.
1
2
3
4
Dip-switch1= operation of courtesy light
ON
Off: normal (default)
On: flashing
1
2
3
4
Dip-switch2= reduction of closing time after passing the
photocell.
Off: no change (default)
On: the closing time is reduced to 1/4th of the total value.
Dip-switch3= Automatic closure if the gate movement is
stopped with button "P.P" in the opening phase.
Off: disabled automatic closure (default)
On: enabled automatic closure.
Dip-switch4= Operation of the flashing light.
Off: constant flashing (default)
On: slow flashing in the opening phase, rapid flashing in the
closing phase.
Dip-switch1= Flashing during the dwell time for the automatic
ON
closure.
Off: flashing light off (default)
1
2
3
4
On: flashing light on
Dip-switch2= Switching of photocells during the open. phase.
Off: no activation (default)
On: stop until the photocell remains activated.
Dip-switch3= Braking at end of opening.
Off: braking activated
On: braking desactivated (default).
Dip-switch4= Not in use.
ON
1
2
3
4
ON
1
2
3
4
Continued ...
Table 5
Selectable values - part 2
Dsw1
Dsw2
Dsw3
Dsw4
Off
Off
Off
Off
On
Off
Off
Off
Off
On
Off
Off
On
On
Off
Off
Off
Off
On
Off
On
Off
On
Off
Off
On
On
Off
On
On
On
Off
Off
Off
Off
On
On
Off
Off
On
Off
On
Off
On
On
On
Off
On
Off
Off
On
On
On
Off
On
On
Off
On
On
On
On
On
On
On
Dsw1
Dsw2
Dsw3
Dsw4
Off
Off
Off
Off
On
Off
Off
Off
Off
On
Off
Off
On
On
Off
Off
Off
Off
On
Off
On
Off
On
Off
Off
On
On
Off
On
On
On
Off
Off
Off
Off
On
On
Off
Off
On
Off
On
Off
On
On
On
Off
On
Off
Off
On
On
On
Off
On
On
Off
On
On
On
On
On
On
On
Seconds
20
40
60
80 (default)
100
120
140
160
180
200
220
240
260
280
300
320
Seconds
0
20
40
60
80 (default)
100
120
140
160
180
200
220
240
260
280
300

Publicidad