Maintenance; Remote Injecting - DOSMATIC SUPERDOS 30 Manual De Operación

Tabla de contenido

Publicidad

Remote Injector
Kit shown on a
single injector.
Rinse Injector After Each Use
Additive allowed to remain in injector can dry, foul or
damage the lower end at the next start-up. Place suction
tube into a 1 qt. (0.95 liters) or more container of fresh
filtered water. Flow fresh water through the injector by
operating until container is empty. This procedure is not
needed for continuous operation.
Clean Solution Container
Keep covered to prevent dirt, flies and flying debris from
entering the container. Rinse container thoroughly and often.
Do not mix chemicals together that might react and cause a
precipitate. Use FILTERED fluid when filling container.
Clean Suction Tube Filter Screen
Inspect each time new solution is added. Clean filter
screen (#27) and suction tube (#25) as necessary by
rinsing in fresh water. Replace if necessary. Keep filter
screen off bottom of solution container to prevent dirt
and precipitate from clogging filter.
Clean Inlet Filter
Clean or replace inlet filter as required to increase the life
of the unit as well as reduce pressure loss.
Bypass Injector
When not in use place the injector in bypass mode by
using the three valve bypass (preferred) or turn the
on/off lever on the top of the injector to the off position.
Storage
For extended storage, rinse injector (see "Rinse Injector
After Each Use") and place underwater in a container.
Apply monthly, <0.1 oz. (29 ml) of chlorine bleach to
avoid algae growth. KEEP FROM FREEZING.
English: 10

Remote Injecting

Fig. 6
Fig. 7
Remote Injector
Kit shown in a
series.

Maintenance

Reference numbers refer to Page 13 - 18
Remote Injector Kit
(not included)
Is recommended for the following:
Single Injector:
To prevent mineral buildup within the body of the unit.
Use when injecting chemicals that cause minerals to
precipitate from fluid (see Fig. 6)
Injectors In a Series:
When injecting multiple chemical injections, using two
or more injectors. Each injector adds chemical to the
fluid(water) system, while bypassing the next injector and
eliminating the potential damage to that injector (see Fig. 7).
NOTE: when mixing more than one chemical, always
refer to your chemical manufacturer information guide
for proper application. Contact your local distributor or
Dosmatic customer service for information or to order.
Perform these maintenance
procedures to extend the life of your unit.
Refer to page 14 - 15
SuperDos 30 (0.3%) (0.3% PAA) Models
Every 3 - 6
Every 6 - 12
Months
months
1. Clean seal areas
1. Replace #17 O-ring and
(# 17 & 13).
#51 Lower Shaft Assy.
2. Check #17 O-ring,
2. Clean and/or replace
#68 Cylinder, clean
#13 Check Poppet, #11
and/or replace as
Suction Tube Fitting.
necessary.
Refer to page 16, 17 & 18
SuperDos 30 (2.5%), (2.5% WSP), (5%) Models
Every 3 - 6
Every 6 - 12
Months
1. Clean seal areas (#
1. Replace #17 O-ring
13 & 14, #44 - WSP).
and #44 Dosage piston/
2. Check #17 O-ring,
gasket (WSP model).
#7 Cylinder, clean
Clean and/or replace.
and/or replace as
2. #13 Check Poppet ,
necessary.
#11 Suction Tube Fitting.
Kit Part Numbers
012705
Replace as
necessary
1. #68 Cylinder
2. #51 Lower Shaft
Assembly
Replace as
months
necessary
1. #7 Cylinder
2. #14 (#44 - WSP)
O-ring

Publicidad

Tabla de contenido
loading

Tabla de contenido