Ametek Sorensen XEL Serie Manual De Instrucciones página 48

Fuentes de alimentación de cc lineal de precisión
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

LSE<n> <nrf>
Set the value of LSE<n>, Limit Event Status Enable Register <n>, to <nrf>
LSE<n>?
Return the value of LSE<n>, Limit Event Status Enable Register <n> - response
is <nr1><rmt>
SAV<n> <nrf>
Save the current set-up of output <n> to the set-up store specified by <nrf>
where <nrf> can be 0-9.
RCL<n> <nrf>
Recall a set up for output <n> from the set-up store specified by <nrf> where
<nrf> can be 0-9.
RATIO <nrf>
Set the ratio of output 2 (slave) to output 1 (master) in tracking mode to <nrf>,
where <nrf> is the ratio in percent (0 to 100).
RATIO?
Query the ratio of output 2 (slave) to output 1 (master) in tracking mode. The
response is <nrf>, where <nrf> is the ratio in percent (0 to 100).
System and Status Commands
*CLS
Clear Status. Clears the Status structure. This indirectly clears the Status Byte
Register.
EER?
Query and clear Execution Error Register. The response format is nr1<rmt>.
*ESE <nrf>
Set the Standard Event Status Enable Register to the value of <nrf>
*ESE?
Returns the value in the Standard Event Status Enable Register in <nr1>
numeric format. The syntax of the response is <nr1><rmt>
*ESR?
Returns the value in the Standard Event Status Register in <nr1> numeric
format. The register is then cleared. The response is <nr1><rmt>. See Status
Reporting section for details.
*IST?
Returns ist local message as defined by IEEE Std. 488.2. The syntax of the
response is 0<rmt>, if the local message is false, or 1<rmt>, if the local message
is true.
*OPC
Sets the Operation Complete bit (bit 0) in the Standard Event Status Register.
This will happen immediately the command is executed because of the
sequential nature of all operations.
*OPC?
Query Operation Complete status. The response is always 1<rmt> and will be
available immediately the command is executed because all commands are
sequential.
*PRE <nrf>
Set the Parallel Poll Enable Register to the value <nrf>.
*PRE?
Returns the value in the Parallel Poll Enable Register in <nr1> numeric format.
The syntax of the response is <nr1><rmt>
QER?
Query and clear Query Error Register. The response format is nr1<rmt>
*RST
Resets the instrument to the remote control default settings with the exception of
all remote interface settings and stored set-ups. (see Remote Operation
Defaults paragraph in the Remote Interface Operation section)
*SRE <nrf>
Set the Service Request Enable Register to <nrf>.
*SRE?
Returns the value of the Service Request Enable Register in <nr1> numeric
format. The syntax of the response is<nr1><rmt>
*STB?
Returns the value of the Status Byte Register in <nr1> numeric format. The
syntax of the response is<nr1><rmt>
*WAI
Wait for Operation Complete true. As all commands are completely executed
before the next is started this command takes no additional action.