Setting of menu items
SETTING menu
[6] INTELLIGENT1
AGC GAIN STEP [NORMAL, MAX]
The AGC gain increment or decrement step
is selected using this menu item.
When LOCK is established as the
INTELLIGENT status, no changes can be
made.
The AGC GAIN STEP setting is switched
when the ENTER operation has been
performed.
NORMAL:
In the case of underexposure, the
gain is incremented from 0 dB
to AGC MAX GAIN in very small
steps. Conversely, in the case of
overexposure, it is decremented
from AGC MAX GAIN to 0 dB in
very small steps.
MAX: In the case of underexposure,
the gain is incremented straight
from 0 dB to AGC MAX GAIN.
Conversely, in the case of
overexposure, it is decremented
straight from AGC MAX GAIN to
0 dB.
When MAX is selected, set AGC
MAX GAIN in such a way that the
lens iris adjustment range is not
exceeded.
(If it is set so that this range is
exceeded, iris hunting may occur.)
HI LIGHT DETECT [01 to 10]
When the effective image is exposed to
the light from a spotlight, one of 10 levels
for ignoring the effect of the light can be
selected.
The reaction to the light from the spotlight
becomes greater as the figure increases.