Troubleshooting
Solution
If the alarm persists when there is no electric vehicle connected, contact the telephone support service.
Charging sequence fault (error code 0256)
Description
Incorrect charging sequence or disconnection of the vehicle during charging.
Solution
If the alarm appears due to the vehicle's disconnection during the charge session, it will disappear upon
completing the session.
If the alarm persists when there is no charge session in progress, contact the telephone assistance.
Maximum permitted charge current (error code 0512)
Description
The vehicle has not respected the maximum charge current allowed during a maximum established time.
Solution
The alarm will disappear upon completion of the charge session of the electric vehicle causing the alarm.
Communication failure with the power manager (error code 1024)
Description
Failure in the communication between the station and power manager. This error appears if the station is
configured to work together with a power manager, but it is not present.
Solution
Check the communication between the station and power manager. If there is no power manager, disable it in the
station's configuration.
The keypad does not work
Description
The charging station keypad does not respond.
Solution
Make sure that the keypad cable is correctly inserted inside the unit and that there are no loose or incorrectly
inserted cables in the control card.
If the error persists, contact the telephone support service.
ABA2022IQM01_ - 7.55.4.413.0 - Installation and Operation Manual
Gewiss
EN
ES
FR
IT
33