Lamborghini Caloreclima ECO 8 Manual Para La Installación Y El Mentenimiento página 44

Quemadores para gasóleo
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

PIPE FILTER - POSITIONING FAN
WARNING: in the event of a dangerous situation cut power by turning the main switch
to OFF and stop fuel flow via the relative gate
Close the fuel aspiration gate and, depending on the type, proceed with thorough clea-
ning of the filtration component. To check whether the air gate fan is clean or to check
the combustion head proceed as follows:
- Remove the cover (23) by loosening the screw (22).
- Loosen the lower screws (32) completely.
- Loosen the central screw too.
- Parzially loosen the upper screws (14) too.
- Release by raising the component support plate (34) and hook it in its seat as illustra-
ted in fig. 16.
Doing the above provides the conditions needed to check whether the internal burner
parts are clean and, where necessary, to replace the motor-fan unit. When re-assem-
bling make sure that you observe the gap illustrated.