Troubleshooting - Powerfix Profi HG00962A Instrucciones De Utilización Y De Seguridad

Ocultar thumbs Ver también para HG00962A:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 59
Deviation from a reference value (see fig. D):
j
Measure a reference object (in this case A).
j
Leave the measuring jaws
the key to obtain the zero setting (ZERO)
j
Then measure the second object. The LCD display
shows the deviation of the measurement of the second object
to that of the reference object (A).
Measuring the thickness of the floor of an object
(see fig. E):
j
First measure the depth of the object.
j
Leave the depth blade
to obtain the zero position (ZERO)
j
Now measure the entire object. The LCD display
shows the thickness of the floor of the object.
Measuring the distance between two identical
holes (see fig. F):
j
First measure one of the two, equally sized holes.
j
Leave the measuring jaws
the key to obtain the zero position (ZERO)
j
Now measure the total dimension. The LCD display
shows the average distance.
Characteristics of metric ISO screw threads:
Nominal diameter:
[mm]
3
4
5
6
8
10
12
16
20

Troubleshooting

Q
The device contains sensitive electronic components. That is why
it experiences interference when in close proximity to radio
transmission devices. If any indication errors appear in the
display, remove such devices out of the proximity of the calliper.
/
2
in this position and press the key
6
/
2
Increase:
Core diameter:
[mm
]
[mm]
-1
0.5
2.46
0.7
3.24
0.8
4.13
1
4.92
1.25
6.65
1.5
8.38
1.75
10.11
2
13.84
2.5
17.29
in this position and press
11
.
9
.
9
in this position and press
11
9
now
5
now
5
.
now
5
Drill
diameter:
[mm]
2.5
3.3
4.2
5
6.8
8.5
10.2
14
17.5
GB/IE 23

Publicidad

Tabla de contenido
loading

Tabla de contenido