PROBLEM
There is no spark
the pilot does not switch on when
there is a spark
the burner does not switch off when
the water turns off
the exchanger blade becomes dirty
in a small amount of time
there is a smell of gas
there is a smell of gas
CAUSE
- exhausted battery
- electrical cable of device is disconnected
- electrical card is broken
- there isn't sufficient water pressure
- the membrane is broken
- the electrode is damaged
- safety device broken
- no gas supply
- air in the gas tubes
- grime on the gas shutter
- valve piston or stem is locked in open posi-
tion
- micro lever is locked in open position
- If an LPG supply, check the gas pressure
- poor draught or dusty surroundings
- yellow flame
- excess gas consumption
- due to the loss of gas in the tubes, check the
tubes and find the leak
- it can be caused by obstruction in the flue gas
circuit
- excess gas consumption
- substitute
- insert
- test, substitute
- repair the device to guarantee pressure, rota-
te the selector knob all the way to the right
- substitute
- substitute
- substitute
- open the gas tap
- release gas
- test, clean
- disassemble, clean and eventually substitute
- test
- regulate and if necessary substitute the tank
pressure regulator
- check the smoke channel efficiency
- Check the gas type and clean the burner
- check and regulate
- do not activate electric switches or any object
that produces sparks in local area
- check the efficiency of the smoke channel
and the flue gas conduit
- check and regulate