BFT LEO B CBB 3 400 W01 Instrucciones De Instalación página 10

Cuadro de mandos
Ocultar thumbs Ver también para LEO B CBB 3 400 W01:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 27
x 2
language
autoset
l. s w adj
LIMIT SWITCH
ADJUSTMENT
Control unit software version
stat
OK
vers
- +
No total
manoeuvres (in hundreds)
n. cycles
OK
- +
List of last 30 errors
OK
err
10 -
LEO B CBB 3 400 W 01
ACCESS MENUS Fig. 1
See PARAMETERS MENU
See LOGIC MENU
Diagnostics
code
STRE
START E external start input activated
STRI
START I internal start input activated
OPEN
OPEN input activated
CLS
CLOSE input activated
PED pedestrian input activated
PED
TIMER input activated
TIME
bft . . .
+/-
STOP input activated
STOP
PHOT photocell input activated
PHOT
0000
PHOT OP opening photocell input activated
PHOP
+/-
PHOT CL closing photocell input activated
PHCL
BAR safety edge input activated
BAR
01.33
SWC motor closing limit switch input activated
SWC
02.01
SWO motor opening limit switch input activated
SWO
........
Mechanical release activated
rls
30.15
ER01
Photocell test failed
+/-
ER02
Safety edge test failed
ER03
Opening photocell test failed
Closing photocell test failed
ER04
er06
8k2 safety edge test failed
ER1x
Board hardware test error
*
Encoder error
ER2x
*
ER3x
Reverse due to obstacle - Amperostop
*
ER4x
Thermal cutout
*
ER7x
Internal system supervision control error.
*
*X= 0, 1, .., 9, A, B, C, D, E, F
https://appceso.com
35. 4 0
DESCRIPTION
Scroll up
Scroll down
Con rm/Switch on display
Exit Menù
Obstacle threshold
Instantaneous force motor
NOTES
 
 
 
 
 
 
 
 
 
 
 
 
 
Check position of release
Check photocell connection and/or logic settings
Check safety edge connection and/or logic settings
Check photocell connection and/or param-
eter/logic setting
Check photocell connection and/or param-
eter/logic setting
Check safety edge connection and/or
parameter/logic settings
- Check connections to motor
- Hardware problems with board (contact
technical assistance)
- Motor power cables disconnected.
Reverse 2 phases in the supply terminal.
- Actuator movement is too slow or stopped
with respect to programmed operation.
Check for obstacles in path
Allow automated device to cool
Try switching the board off and back on
again. If the problem persists, contact the
technical assistance department.
 

Publicidad