TABLE "B" - LOGIC MENU - (LOGIC)
Logic
Definition
Automatic Closing
TCA
Time
STEP-BY-STEP
Step-by-step
movement
MOVEMNT
PRE-ALARM
Pre-alarm
HOLD-TO-RUN
Deadman
Block pulses during
IBL OPEN
opening
OPEN IN OTHER
Open in other
direction
DIRECT.
Configuration of
SAFE 1
safety input SAFE 1.
72
Configuration of
SAFE 2
safety input SAFE 2.
74
Configuration of
SAFE 3
safety input SAFE 3.
77
Configuration of
IC 1
command input IC 1.
61
Configuration of
IC 2
command input IC 2.
62
Configuration of
IC 3
command input IC 3.
64
Configuration of
IC 4
command input IC 4.
65
14 -
LEO B CBB 3 400 W 01
INSTALLATION MANUAL
Cross out
Default
setting
used
0
Logic not enabled
0
 
1
Switches automatic closing on
Inputs configured as Start E, Start I,
0
Ped operate with 4-step logic.
Inputs configured as Start E, Start I,
1
Ped operate with 3-step logic. Pulse
during closing reverses movement.
0
 
Inputs configured as Start E, Start I,
2
Ped operate with 2-step logic. Move-
ment reverses with each pulse.
0
The flashing light comes on at the same time as the motor(s) start.
0
 
1
The flashing light comes on approx. 3 seconds before the motor(s) start.
0
Pulse operation.
Deadman mode.
Input 64 is configured as OPEN UP.
Input 65 is configured as CLOSE UP.
1
Operation continues as long as the OPEN UP or CLOSE UP keys are held down.
WARNING: safety devices are not enabled.
Emergency Deadman mode. Usually pulse operation.
If the board fails the safety device tests (photocell or safety edge, Er0x) 3 times in a row, the device is
switched to Deadman mode, which will stay active until the OPEN UP or CLOSE UP keys are released.
0
 
2
Input 64 is configured as OPEN UP.
Input 65 is configured as CLOSE UP.
WARNING: with the device set to Emergency Deadman mode, safety devices are not enabled.
Pulse operation during opening.
Deadman mode during closing.
Input 64 is configured as PULSE OPEN.
3
Input 65 is configured as CLOSE UP.
WARNING: safety devices are not enabled during closing.
0
Pulse from inputs configured as Start E, Start I, Ped has effect during opening.
0
 
1
Pulse from inputs configured as Start E, Start I, Ped has no effect during opening.
0
Standard operating mode (See Fig.D1).
0
 
1
Opens in other direction to standard operating mode (See Fig.D1).
0
Input configured as Phot (photocell).
1
Input configured as Phot test (tested photocell).
0
2
Input configured as Phot op (photocell active during opening only).
3
Input configured as Phot op test (tested photocell active during opening only).
 
4
Input configured as Phot cl (photocell active during closing only).
5
Input configured as Phot cl test (tested photocell active during closing only).
6
6
Input configured as Bar, safety edge.
7
Input configured as Bar, tested safety edge.
8
Input configured as Bar 8k2.
0
Input configured as Phot (photocell).
1
Input configured as Phot test (tested photocell).
2
Input configured as Phot op (photocell active during opening only).
3
Input configured as Phot op test (tested photocell active during opening only).
2
 
4
Input configured as Phot cl (photocell active during closing only).
5
Input configured as Phot cl test (tested photocell active during closing only).
6
Input configured as Bar, safety edge.
7
Input configured as Bar, tested safety edge.
0
Input configured as Start E.
0
1
Input configured as Start I.
2
Input configured as Open.
4
3
Input configured as Close.
 
4
Input configured as Ped.
2
5
Input configured as Timer.
3
6
Input configured as Timer Pedestrian.
https://appceso.com
Optional extras
step-by-step mov.
2 STEP
3 STEP
CLOSED
OPENS
OPENS
DURING
CLOSING
OPEN
CLOSES
CLOSES
DURING
STOP + TCA STOP + TCA
OPENING
AFTER STOP
OPENS
OPENS
4 STEP
OPENS
STOPS
CLOSES
OPENS