Installation Instructions
Electrical connection (non-Canada) - 4 wire cord
4-wire receptacle
(NEMA type 14-30R)
WARNING
ELECTRICAL SHOCK HAZARD
Failure to disconnect power source before servicing
could result in personal injury or even death.
1 Turn off power supply to outlet.
2 Remove the screw securing the terminal block access
cover in the lower corner on the back of the dryer.
3 Install a UL-approved strain relief according to the
power cord/strain relief manufacturer's instructions
in the power cord entry hole below the access panel.
At this time, the strain relief should be loosely in
place.
4 Thread an UNPLUGGED, UL-approved, 30 amp.
power cord, NEMA 14-30 type ST or SRDT, through
the strain relief.
5 Disconnect the dryer internal ground wire (WHITE)
from the ground screw (GREEN) next to the terminal
block.
6 Attach the power cord ground wire (GREEN) to the
ground screw (GREEN) next to the terminal block.
Tighten the screw securely.
7 Move the dryer internal ground wire (WHITE) to the
terminal block and attach it along with the neutral
(WHITE) power cord wire conductor to the center,
SILVER colored terminal on the terminal block.
Tighten the screw securely.
8 Attach the RED and BLACK power cord conductors
to the outer, BRASS colored terminals on the terminal
block. Tighten both screws securely.
WARNING
ELECTRICAL SHOCK HAZARD
Do not make a sharp bend or crimp wiring/conductor at
connections.
9 Follow manufacturer's guidelines for fi rmly securing
the strain relief and power cord.
10 Reinstall the terminal block cover.
30 AMP
30 AMP
NEMA 14-30
NEMA 14-30
GREEN
ground screw
GREEN
ground wire
Move internal ground
(WHITE) wire to neutral
(silver) terminal for
4-wire system
16
Neutral
Neutral
(WHITE wire)
(WHITE wire)
Ground
Ground
(GREEN wire)
(GREEN wire)
power wire
BLACK
or RED
power wire
Neutral
terminal
WHITE
neutral wire
BLACK
or RED