Electrical requirements for Laundry Center with gas dryer
CIRCUIT - Individual, properly polarized and grounded 15
amp. branch circuit fused with 15 amp. time delay fuse
or circuit breaker.
POWER SUPPLY - 2-wire, with ground, 120 volt, single
phase, 60 Hz, Alternating Current.
POWER SUPPLY CORD - The dryer is equipped with a 120
volt 3-wire power cord.
GROUNDING CONNECTION - See "Grounding
requirements" in Electrical Installation section.

Gas supply requirements

WARNING
EXPLOSION HAZARD
Uncoated copper tubing will corrode when subjected
to natural gas, causing gas leaks. Use ONLY black iron,
stainless steel, or plastic-coated brass piping for gas
supply.
1 Installation MUST conform with local codes, or in
the absence of local codes, with the National Fuel
Gas Code, ANSI Z223.1 (latest edition).
2 The gas supply line should be 1/2 inch (1.27 cm)
pipe.
3 If codes allow, fl exible metal tubing may be used to
connect your dryer to the gas supply line. The tubing
MUST be constructed of stainless steel or plastic-
coated brass.

Water supply requirements

Hot and cold water faucets MUST be installed within 42
inches (107 cm) of your washer's water inlet. The faucets
MUST be 3/4 inch (1.9 cm) with threading for laundry
hose connection. Water pressure MUST be between 10 psi
(0.69 bars) and 120 psi (8.27 bars). Pressure diff erence
between hot and cold cannot be more than 10 psi. Your
water department can advise you of your water pressure.
Installation Requirements
Grounding type
Grounding type
wall receptacl
wa
ll receptacle
Po Power cord with
wer cord with
3-prong gr grounded plug
3-prong
ounded plug
4 The gas supply line MUST have an individual shutoff
valve.
5 A 1/8 inch (0.32 cm) N.P.T. plugged tapping,
accessible for test gauge connection, MUST be
installed immediately upstream of the gas supply
connection to the dryer.
6 The dryer MUST be disconnected from the gas
supply piping system during any pressure testing
of the gas supply piping system at test pressures in
excess of 1/2 psig (3.45 kPa).
7 The dryer MUST be isolated from the gas supply
piping system during any pressure testing of the gas
supply piping system at test pressures equal to or
less than 1/2 psig (3.45 kPa).
8 Connections for the gas supply must comply with the
Standard for Connectors for Gas Appliances, ANSI
Z21.24.
NOTE
Washers connected to water supplies with lower inlet
pressure will experience longer fi lling times and may not
complete cycles as quickly.
5
Do not, under
Do not,
under
an any cir
y circumstances,
cumstances,
cut, remo
cut,
remove ve,
or bypass th
or b
ypass the
gr grounding pr
ounding prong.
ong.