12
UK
ELECTRICAL CONNECTIONS: TERMINAL BOARDS)
1
PHOTOCELL input (NC)
STOP input (NC). Causes a functional stop
2
3
4
COMMON for STOP-START-PHOTOCELLS
12 VDC output for power supply, max.
5 - 6
2 pairs of photocells (6 = POSITIVE)
12 VDC output for ELECTRIC LOCK power
7 - 8
9 - 10
12 VDC output for FLASHLIGHT ( max. 15 W )
if using with battery, the "optional cable" accessory specifically designed for recharging is
required. Connecting a battery without this special cable may cause IRREPARABLE DAMAGE TO
THE CONTROL UNIT.
FUNCTION SELECTION VIA DIP-SWITCH SW1
DIP
ON
1
CONDOMINIUM program
2
STEP-BY-STEP program (*)
(Only with DIP 1 OFF)
DECELERATION phase in the last seconds
3
of each manoeuvre (*)
Water Hammer enable to facilitate electric
4
lock release
5
PROGRAMMAZIONE TEMPI
6
PHOTOCELL input disabled (terminals 1-4) (*)
(*) DEFAULT SETTINGS
With DIP2 OFF: should the power fail during opening, closing or pause, when the power is restored
the control unit automatically performs a full closing manoeuvre of the gate.
of the motion
START input (NO)
supply (max. 15 W)
11- 12 Output Motor 2 ( 12 positive during opening )
Output Motor 1 (= it opens for first) to be
13- 14
used for pedestrian gate
(14 positive during opening)
15
ANTENNA ground
16
ANTENNA signal
CN4 -
Ingresso per BATTERIA TAMPONE 12Vdc
CN5 (*)
(CN4 = positivo)
CN2 -
Input for 12 VDC BUFFER BATTERY
CN3
(CN4 = positive)
F - N
Power supply, 230 VAC, single-phase, 50/60 Hz
OFF
Uninfluential (see DIP2) (*)
RESIDENTIAL program
(step-by-step with automatic reclosing)
DECELERATION disabled
Water Hammer disabled (*)
Normal operation (*)
PHOTOCELL input enabled
F12E