The following table shows what occurs each time a START COMMAND is given depending on the program selected
and the state in which the gate is at that moment.
PROGRAMMA
SELEZIONATO
STEP-BY-STEP
RESIDENTIAL
CONDOMINIUM
ADJUSTING THE TRIMMERS PT1 (motor 1) and PT2 (motor 2)
Turning the trimmers clockwise increases the AMPEROMETRIC LOCKING THRESHOLD of the respective motor
(2.5 to 5.5 A).
The intervention of the current limiter both during opening and closing causes an immediate stop of the movement.
DEFAULT SETTINGS: trimmers adjusted to half their stroke.
To facilitate the PROGRAMMING phase, let the control unit or the r ol receiver learn a remote
control (see CODE LEARNING), otherwise the START command must be given by closing the
contact to the terminals 3-4.
Start programming from the condition in which the GATE IS COMPLETELY CLOSED.
To enable deceleration set DIP3 to ON before starting to program.
TIME PROGRAMMING
(run time, pause time, gate phase shift time, pedestrian cycle)
1) GATE CLOSED: set DIP5 to ON.
2) Press START: Wing 1 starts opening and after 2 seconds also Wing 2.
3) When Wing 1 arrives against the mechanical stop, it stops automatically. WING 1 STOPS.
4) When Wing 2 arrives against the mechanical stop, it stops automatically. WING 2 STOPS.
5) The flashlight goes off and counting of the pause time starts. After the desired time (max. 240 s) press START:
WING 2 STARTS CLOSING.
6) Wait for the time necessary to assure the desired gate phase shift and then press START: WING 1 STARTS
CLOSING.
7) The control unit does not accept any more commands until the WINGS HAVE STOPPED against the respective
mechanical closing stops. GATE CLOSED.
8) Set DIP5 to OFF to finish programming.
If the control unit is coupled to the receiver code AU01780 it is also possible to control partial opening of only WING 1
(pedestrian cycle) using the 2nd channel of the remote control (previously stored).
To program the PEDESTRIAN CYCLE operate as described above (steps 1, 2, 3, 5, 6, 7, 8), but give the command
through the 2nd CHANNEL of the remote control.
WARNING:
- the mechanical end-stops must be used;
- the timeprogramming logic requires that motor 2 arrives before motor 1 at the mechanical closing stop.
The gate is
The gate is
CLOSED
OPENING
OPENS
STOPS
STOPS and enables
counting of the pause
OPENS
time for the next
automatic reclosing
OPENS
IGNORED
– double swing gates
The gate is
OPEN
CHIUDE
CLOSES
(the gate would close
automatically at the end
of the pause time)
Reinitialises counting of
the pause time at the
end of which it closes
automatically
13
UK
The gate is
CLOSING
STOPS
STOPS AND
RE-OPENS
STOPS AND
RE-OPENS