8 MAIN COMPONENTS
Heating expansion vessel 6L
Insulated heating header tank
Circulation pump RKC130
Power PCB MAC with support
Heating PCB
Temperature sensor white
Temperature sensor black
15 kW heating resistance & joint 140
18 kW heating resistance & joint 140
9 MAINTENANCE & CARE
Gabarrón electric boilers do not require any special maintenance for a prolonged and trouble-free life however the following
points should be observed.
- Check and maintain the heating system pressure between 1 & 1.5 bar when cold. Frequent re-filling of the system could
cause scaling and corrosion and should be avoided. Regular pressure loss could indicate a leak and should be investigated
promptly.
CAUTION: Under no circumstances should the boiler be switched on when the system is dry.
- Keep the ventilation openings on the boiler clear to ensure correct operation and protect from overheating. Do not place
or store objects on the boiler.
- Protect against freezing by ensuring power is maintained to the boiler at all times. In dwellings frequently un-occupied or at
risk of freezing an appropriate anti-freeze can be added to the heating system at a concentration of not more than 30% by
volume. Otherwise it is recommended to isolate the power and completely drain the heating and hot water systems.
- The outer case can be cleaned with a damp cloth having first isolated the boiler from the mains. Do not use solvents or
abrasive cleaners.
10 ENVIRONMENTAL INFORMATION
Gabarrón boilers are manufactured within a certified environmental management system. From the design stage, all the
production phases are performed taking into account the most rigorous environmental requirements. For example, the
selection of materials involves guaranteeing their biodegradability, re-use and recycling.
When this boiler's long, useful life is over; it must be handed in to an electrical equipment collection point for proper
recycling. By ensuring that this product is correctly disposed of, you will help to avoid any possible negative effects on the
environment and public health that could occur if this product is not properly handled. To obtain more detailed information
on the recycling of this product, contact your local authority, your waste disposal service or the shop where you purchased
the product.
These regulations only apply in EU member countries.
ref. 60091510
¾" heating flow detector
ref. 60101700
0-4 bar pressure gauge
100°C thermal limiter
ref. 60190076
ref. 60105595
Automatic purge
ref. 60105590
3 bar central heating relief valve
ref. 60105600
Keyboard MAC
ref. 60105605
ref. 60100750
ref. 60100760
39
ref. 60100805
ref. 60100820
ref. 60101860
ref. 60091280
ref. 60100840
ref. 60105555