DIP
Modes and functions
DIP1
DIP2
Advance warning
DIP3
Key commands using ST1 and ST2
DIP4
Automatic or step-by-step mode
Automatic mode optional
DIP5
(only if DIP4 = ON)
DIP6
Opening photocell testing
DIP7
Encoder
DIP8
Interlocking mode (with FT1)
DIP9
Closing photocell testing
DIP10 No function
T.LG: fan operation time
Regulate the time the operator cooling fan is working.
• Minimum value: 3 seconds; maximum value: 90
seconds
12
Function and mode selection using SW2 (DIP1 = OFF)
Option
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
Potentiometer adjustment
Effect
the flashing light comes on and the operation begins after a 3
second warning
the flashing light comes on and the operation begins
immediately
ST1: opening command; ST2: closing command
ST1: opening and closing commands; ST2: no function
automatic mode (the barrier closes automatically once standby
time has passed, adjusted using T.E.)
step-by-step mode (the barrier only closes when receiving the
key command)
during standby, the barrier obeys the key commands (can be
closed before standby time finishes)
the barrier cannot be closed until standby time finishes; key
commands will cause standby time to restart
testing enabled
testing disabled
encoder enabled
encoder disabled
interlocking mode enabled: the barrier closes if SG.C is enabled
during standby time (in automatic mode)
interlocking mode disabled
testing enabled
testing disabled
always place in OFF
T.E: barrier open standby time
If automatic or optional automatic operation mode has
been programmed, adjust T.E. to set standby time with
the barrier open (before starting to close automatically).
• Minimum value: 0 seconds; maximum value: 90
seconds
P.M: motor torque
Use P.M. to adjust the maximum motor power value.
Torque adjustment, respecting the maximum
closing forces set out in Standard EN12453:2000.
Make the measurements as described in Standard
EN 12445:2000.