material (textile, electronic, wood, glass, paper wall etc.) In this case the isolation of these
materials is obligatory (Glasswool, Class A-1, EN 13501-1) and the clearance for the appliance
must not be less than 1300 mm from the back wall and 400 mm from the sides if they were. The
same distance of 400 mm must be respected in the roof. All combustible items (furniture, Hi-fi,
DVD player, TV or carpets) must have a minimum clearance of 1000 mm from the front of
appliance.
1.5 Ventilation. Permanent ventilation is required in the room housing the appliance. You must
consider other ventilation devices (air conditioning, fans or heating) that may work
simultaneously. The air going out must be balanced with air coming in. If necessary install an
80mm diameter inlet in the room.
1.6. Type of fireplace. It is a free appliance so must not be covered by any material.
1.7. Appliance assembly.
1.7.1. Platform assembly
bearing in mind that it must be central to the chimney and flue exit.
1.7.2. Stand assembly
1.7.3. Appliance's fixation
screws M10x20.
1.7.4. Level the appliance
M10x30.
1.7.5. Installation of the flue pipe
required.
1.7.6. Installation of the flue pipe cover
the back piece, fit the detachable flue collar, fit the front piece of flue.
The flue pipe can now be cut to the length of the room. Do not cover the holes for the ceiling
crest.
1.7.7. Installation of the ceiling crest
screws provided.
1.8. Heat-resistant panels assembly. These panels are set into a box and they are black on
one side, without colouring on the other. In this way, the colour wanted can be chosen. Follow
the steps to collocate properly.
1.8.1. Base panel
(11-12).
central one afterwards
1.8.2. Back panels
put the piece in "U" between this panels and finally the central piece. Once all panels are
placed, put the ash box and grill in the space between base panels
1.8.3. Foot Heat-resistant panel
as indicate.
1.8.4. Diagram for heat-resistant panel
1.9. Acces for cleanning and security. It is possible to sweep the appliance and flue from the
inside.
Position the platform where the appliance is going to be installed,
(1).
Place the stand on the platform.
(2).
Next, put the chimney over the stand and fix with 2 hexagonal
(3).
To level the appliance on the wall use 2 hexagonal screws
(4).
(5)
First the base panels must be collocated with the side pieces and the
The procedures is the same, start with two lateral pieces, then
(13-14-15-16).
(19-20).
.The flue collar is detachable. Fit the flue collar as
The flue pipe cover is in two pieces. Install
(6-7-8-9).
Fix the ceiling crest to the roof using the plugs and
(10).
To secure the panels, use the "U" plates and put them
.
Componentes:
2 Units of 400x200x30 panels
1 Units of 200x80x30 panel
3 Units of 400x230x30 panels
Collocation:
1. 400x200x30 panels
2. 200x80x30 panel
3. 400x230x30 panels
(17-18).
(A)
(B)
(C)