Palazzetti ECOFIRE INSERIMENTO IDRO 18 Generalidades - Advertencias - Instalación - Mantenimiento página 39

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

6.6.4 Operation with room probe
In certain circumstances the stove may need to
modulate operation based on the temperature read
by the room probe tted on the stove.
For this purpose it is necessary to bring the probe
environment present on the stove ( g. 6.10 - B) in a
location outside coating that read the correct room
temperature.
The stove must be set to con guration 2 following
the instructions shown in the paragraph on "Initial
con guration".
6.6.5 Connection to a storage tank with coil
The stove can be used to maintain the temperature
inside a storage tank tted with coil.
In this case simply disconnect the external
temperature probe from the stove and t it in the
probe socket on the storage tank.
The stove must be set to con guration 3 following
the instructions shown in the paragraph on "Initial
con guration".
6.6.6 Connection to a storage tank without coil
The stove can be used to maintain the temperature
inside a storage tank without coil.
In this case simply disconnect the external
temperature probe from the stove and t it in the
probe socket on the storage tank.
The stove must be set to con guration 4 following
the instructions shown in the paragraph on "Initial
con guration".
To ensure that the cables do not affect the operation
of the stove, run them through the exible rod on
the back of the stove itself.
39

Publicidad

Tabla de contenido
loading

Tabla de contenido