1 Starting text of the message, for e.g. lo-
cation or description of the unit, max.
length 20 characters
2 "Alarm/Switch1" tab
3 Telephone number to which the inter-
ruption messages are sent
4 Telephone number where the feedback
is to be sent during remote operations
Note
Feedback during remote operations can
only be sent to the receivers who have
been registered in this screen.
Setting up additional receivers for fault
messages
In addition to the receivers mentioned
above, messages can also be sent simulta-
neously to other telephone numbers.
Click "Other Receivers" tab.
1 List of telephone numbers
2 Fault/error messages
3 "Other Receivers" tab.
You can enter a maximum of 20 differ-
–
ent additional receivers in the list of tel-
ephone numbers.
Each message can be sent to a maxi-
–
mum of 10 receivers.
The respective message is sent to the
–
receivers who are checked in the col-
umn for the message with a tick mark.
8
Selective Call Acceptance
Note
Activating the selective call acceptance
prevents other callers from scanning the
data of the plant. Then only the SMS com-
mands sent by registered telephone num-
bers will be accepted.
The transmission of telephone numbers
must be activated on the caller's telephone.
Click "Access Protection" tab; you can
now modify the settings given below it.
1 Tick mark = Selective call acceptance is
active
2 List of telephone numbers that are al-
lowed to remotely operate the SB wash-
ing unit
3 "Access Protection" tab
Apply settings
When all settings are completed, click
"Send values" button.
Note
If an error message occurs while sending
the value, repeat the process.
Save settings on the PC: Clcik "File" in
the menu bar, click "Save File As", en-
ter the file name and save the file.
Exit the configuration program on the
PC.
Switch off the RDS1 switch.
Disconnect serial cable at PC and con-
nect it to the controls of the SB washing
unit.
Switch on the RDS1 switch - the initiali-
sation process will be run.
The initialization process is completed
after approx. 90 seconds.
The "Power" and "Status" LEDs start to
glow.
The "Signal" LED displays the strength
of the reception signal. Faster the LED
blinks, so much better is the reception.
3
-
EN
Check function
Release the fault in the unit (for e.g.
press engine protection switch).
The GSM modem will generate a mes-
–
sage approx. 20 seconds after the oc-
currence of the fault. You can hear the
switching of the alarm output on the mo-
dem.
A short while later, the recipients that
–
have been entered will receive a corre-
sponding SMS.
Query counter status - according to de-
scription in the chapter "Query counter
statuses".
After 1 to 2 minutes, the response will
–
reach the designated receivers.