Descargar Imprimir esta página

Enabling Features - Pentair Water Pool and Spa IntelliFlo VF Guia De Inicio Rapido

Ocultar thumbs Ver también para IntelliFlo VF:

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 73
Features 3 – 9
Enabling Features 3 – 9
Setting Flow Rate
Setting Start/Stop
Features – Flow Duration/Rate/Start–Stop Time
Features 3 through 9 enable you to program specifi c fl ows for timed operation.
These features are fully controlled by IntelliFlo's internal clock. You will need to program a fl ow rate
and start/stop time for each feature.
Note: Feature 3 through 9 program times cannot overlap.
When a feature is running, IntelliFlo will monitor m
All sensors are active during any Feature 3 – 9 cycle.
Features must be enabled before they will operate.
To enable, press
Select + Down arrow
Flow Rate for Features 3 – 9
Press
Down arrow
to access Set Flow.
Press
Select
to access the Flow setting.
Press
Left arrow
and
Right arrow
Change values by pressing
Up arrow
When value is set, press
Enter
Times for Features 3 – 9
Press
Down arrow
to select Start Time or Stop Time Setting.
Press
Select
to access the setting.
Press
Left arrow
and
Right arrow
Change values by pressing
Up arrow
When value is set, press
Enter
3
/h and subtract time from the fi lter cycle.
and
Enter
to save the setting.
to select digit to modify.
and
Down
arrow.
to confi rm value and save changes.
to select digit to modify.
and
Down
arrow.
to confi rm value and save changes.
13

Publicidad

loading

Productos relacionados para Pentair Water Pool and Spa IntelliFlo VF