MSA SingleLine SCOUT Manual De Instrucciones página 13

Ocultar thumbs Ver también para SingleLine SCOUT:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 38
NOTICE
The maximum locking torque for the battery cover is 0.7 Nm. Do not overtighten, otherwise the inserts
can be pulled out!
The device shall only be operated with the following battery types:
Energizer L91 Ultimate Lithium
VARTA 6106 (Professional) Lithium
(1)
Open the battery compartment with a Torx T10 spanner.
(2)
Replace the batteries with new ones.
(3)
Refit the cover of the battery compartment. Whilst doing so, check the sealing for damage and
dirt. If the battery cover is damaged, please contact the MSA service. Maximum locking torque
for battery cover: 0.7 Nm. If the sealing is not damaged or soiled, the battery cover is not twisted
or warped and the screws are not overtightened, the device is water tight and ready to use.
After changing the batteries, the device will perform an electronic self test.
Connect to MSA A2 Software using the service mode to make sure time and date settings are up to
date.
Maintenance and Test Schedules
Type of work
1
Changing the batteries
Cleaning
Basic overhaul by manufac-
turer
1
In any case, change the batteries if low battery alarm is indicated.
Start without Pressure
Long press of manual alarm button in standby activates the device in full alarm without pressure.
Service mode
Pressing manual alarm button for more then 10 seconds in standby activates the service mode.
Service mode can be used in combination with MSA A2 Software to change device settings and read
out log memory.
For more information, see MSA A2 Software.
Before use
After use
X
SingleLine SCOUT
Cleaning and Maintenance
Every
Annually
12 years
X
X
GB
13

Publicidad

Tabla de contenido
loading

Tabla de contenido