Changing Oil Of The Vibrating Unit; Exciter Oil Exchange; Engine Oil Change - Zipper Maschinen ZI-RPE120GYN Manual De Instrucciones

Placa compactadora
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

17.2 Changing oil of the Vibrating Unit

17.2.1 Exciter oil exchange

17.3

Engine Oil Change

ZIPPER MASCHINEN GmbH
ZI-RPE120GYN
Waste oils are toxic and must not be released into the
environment! If necessary contact local authorities for information on
proper disposal.
Waste oils are toxic and must not be released into the
environment! If necessary contact local authorities for information on
proper disposal.
1. Remove the lifting frame
2. Loosen the oil drain plug (W) on the rear of the engine.
3. Open the oil tank cap (K). Collect the draining oil in a collecting
container and dispose of it properly!
4. Tighten the oil drain plug again after emptying.
5. Top up with fresh oil via the filling opening (K).
Only use high-quality engine oil!
www.Zipper-Maschinen.at
N O T I C E
1.
Disassemble the V-Belt cover
Remove the screws of the V-Belt cover
and afterwards the cover.
2.
Disassemble the V-Belt
Detension the V-Belt and remove it.
3.
Remove the machine upper part from the
base plate
-
Loosen the 4 screws(1,2,3,4)
-
Lift the upper part off the base plate
-
Open the draining screw on the exciter
(5)
-
Empty used exciter oil
-
Fill in new exciter oil (20W20 or 15W30
is recommended).
Quantity approx.. 200ml
-
Assemble the drain screw again and
tighten it.
4.
Assemble the upper part of the machine
again
5.
Assemble the V-Belt
(check belt tension and adjust if
necessary).
6.
Assemble the belt cover again.