Electrical Connection - Faber 112554019 Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 60
DUCTED VERSION AIR EXHAUST SYSTEM
When installing the ducted version, connect the hood to the
chimney using either a flexible or rigid pipe ø 150 or 120 mm,
the choice of which is left to the installer.
• To install a ø 120 mm air exhaust connection, insert the re-
ducer flange 9 on the hood body outlet.
• Fix the pipe in position using sufficient pipe clamps (not sup-
plied).
• Remove possible charcoal filters.
AIR OUTLET – RECIRCULATION VERSION
• Connect the Flange to the air outlet opening using a rigid or
flexible pipe of ø120 or 150 mm.
• To connect using a ø120 mm pipe, insert the reduction Flange
9 onto the Hood canopy outlet.
• Fasten the pipe using suitable pipe clamps. The materials re-
quired to do so are not provided.
• Fix the directional Grid 8 on the outlet, using 2 screws 12e (2.9
x 9.5) provided.
• Make sure that the activated charcoal filters are present (see
paragraph on Activated Charcoal Filter Maintenance).

ELECTRICAL CONNECTION

• Connect the hood to the mains through a two-pole switch hav-
ing a contact gap of at least 3 mm..
EN
Connections
ø 120
ø 150
9
APPLIANCE
IN LET
1
15

Publicidad

Tabla de contenido
loading

Tabla de contenido