Dimensional Drawing - Xylem Jabsco ParMax 1 Plus Manual De Instrucciones

Bombas compactas de bajo caudal de presión del agua
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 85
Winterizing
CAUTION: Allowing water to freeze in the system may result in damage to the
pump, plumbing system or Exposed Industrial applications. Non-Toxic antifreeze
for potable water may be used with Jabsco pumps. Follow manufacturer's
recommendations. Refer to equipment manufacturer's instructions for their specific
winterizing and drainage procedures. Do not use automotive antifreeze to winterize
potable water systems . These solutions are highly toxic and may cause serious
injury or death if ingested.
1. Drain the water tank. Open tank drain valve. You may use the pump to drain
the tank by opening all the valves in the system. Allow the pump to operate
until the tank is empty. Do not operate the pump more than 15 minutes
continuously.
2. Open all valves and purge the water from the plumbing system. Turn off
power to the pump. Be sure that all the water from the drain lines is drained.
3. Remove quick-connect inlet and outlet fittings from the pump and turn the
pump on to pump out remaining water from the pump head. Be sure to
have a catch pan or a rag under the pump to prevent water from spilling onto
the floor. Turn the pump off once the plumbing is empty. Leave the fittings
disconnected from the pump until the system is ready to be used again.
Make a note on your tank filler that the plumbing is not connected.
4. Be sure that all valves are left open to protect against damage to the
plumbing.

Dimensional Drawing

2.66 [67.6]
1.72 [43.7]
10
2.79 [70.1]
3.30 [83.8]
4.05 [102.9]
6.47 [164.3]
3.37 [85.6]
0.90
2.21 [56.1]
[22.9]
1.90 [48.3]